TX1000 2/2000 REV C
Page 2
Input Specifications
Parameters
Conditions
Min
Typ
Max
Units
Operating Range
47-63Hz
90
264
VAC
Input Current
Nominal line, full load
12
A
Inrush Current
120VAC, 250C, cold start
80
Apk
240VAC, 250C, cold start
160
Apk
Efficiency
Nominal line, full load
70
75
80
%
Holdup
Full load
20
msec
Power Factor (1)
Full load
0.99
Notes: (1) Harmonic currents meet EN61000-3-2
Output Voltages and Maximum Rated Loads
Model
Output Voltage
Output Current
TX10005AASLPLNH
5.0
200A
TX10005BASLPLNH(1)
12.0
84A
TX10005CASLPLNH(1)
15.0
67A
TX10005DASLPLNH(1)
18.0
56A
TX10005EASLPLNH(1)
24.0
42A
TX10005FASLPLNH(1)
28.0
36A
TX10005GASLPLNH(1)
36.0
28A
TX10005HASLPLNH(1)
48.0
21A
TX10005JASLPLNH(1)
20.0
50A
TXD10005KASLPLNH(1)
3.3
182A
TXD10005LASLPLNH(1)
2.5
200A
Notes: (1) Model specified without optional ORing diode; to specify the diode option, replace the letter “N” with the letter “D”, no O-Ring diode on 5V models.
Output Specifications
Parameter
Conditions
Min
Typ
Max
Units
Output Power
All environmental and line conditions
1000
Watts
Voltage Adjustment Range
Relative to nominal output voltage
+5
%
Output Regulation
Line and load (each)
+0.2
%
Minimum Load
0
Amps
PARD
Measured at output terminals, 20MHz
1
% pk-pk
Temperature Coefficient
00 to 500C
+0.2
%/0C
Environmental Specifications
Parameter
Conditions
Min
Typ
Max
Units
Ambient Temperature
Output de-rated linearly to 50% of
(Operating)
rated capacity between 500C and 700C
0
+70
0C
Ambient Temperature
Non-operating
-50
+85
0C
Altitude (Operating)
-200
+10,000
Feet
Altitude (Non-operating)
-200
+50,000
Feet
Shock
Per MIL-STD-810D, Method 516.3, Procedure II, in each axis, including NTSA drop test
Vibration
Per MIL-STD-810D, Method 514.3, Procedure II, in each axis, including NTSA drop test
Cooling
The TX1000 is provided with an internal cooling fan.



Html Pages

1 2 3 4


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com