27 / 44 page ![]() VOUT+ RG RG VIN- VIN+ 0.22 F RF RF RO RO RIT RIT Input From 50- Test Equipment No Connection 49.9 VOUT± Installed to Balance Amplifier VS+ THS4532 VS± Measure With Diff Probe Here Cal Diff Probe + ± VOCM THS4532 www.ti.com SLOS829 – FEBRUARY 2013 Balance Error The circuit shown in Figure 75 is used to measure the balance error of the main differential amplifier. A network analyzer is used as the signal source and the measurement device. The output impedance of the network analyzer is 50 Ω and is DC coupled. RIT and RG are chosen to impedance match to 50Ω and maintain the proper gain. To balance the amplifier, a 49.9 Ω resistor to ground is inserted across RIT on the alternate input. The output is measured using a high impedance differential probe at the summing junction of the two RO resistors, with respect to ground. Figure 75. Balance Error Test Circuit Copyright © 2013, Texas Instruments Incorporated Submit Documentation Feedback 27 Product Folder Links :THS4532 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|