| 전자부품 데이터시트 검색엔진 |
|
DS75 데이터시트(PDF) 2 Page - Dallas Semiconductor |
|
|
|||||||||||||||||||||||||||||
DS75 데이터시트(HTML) 2 Page - Dallas Semiconductor |
|
2 / 13 page ![]() DS75 2 of 13 Applications for the DS75 include personal computers/servers, cellular telephones, office equipment, or any microprocessor–based thermally–sensitive system. DETAILED PIN DESCRIPTION Table 1 PIN SYMBOL DESCRIPTION 1SDA Data input/output pin for 2–wire serial communication port. 2SCL Clock input/output pin for 2–wire serial communication port. 3 O.S. Thermostat output Becomes active when temperature exceeds TOS. Device configuration defines means to clear over–temperature state. 4 GND Ground pin. 5A2 Address input pin. 6A1 Address input pin. 7A0 Address input pin. 8VDD Supply Voltage 2.7V – 5.5V input power pin. OVERVIEW A block diagram of the DS75 is shown in Figure 1. The DS75 consists of five major components: 1. Precision temperature sensor 2. Analog–to–digital converter 3. 2–wire interface electronics 4. Data registers 5. Thermostat comparator The factory–calibrated temperature sensor requires no external components. Upon power–up, the DS75 begins temperature conversions with the default resolution of 9 bits (0.5 °C resolution). The host can periodically read the value in the temperature register, which contains the last completed conversion. As conversions are performed in the background, reading the temperature register does not affect the conversion in progress. In power–sensitive applications, the user can put the DS75 into a shutdown mode, under which the sensor will complete and store the conversion in progress and revert to a low–power standby state. In applications where small incremental temperature changes are critical, the user can change the conversion resolution from 9–bits to 10, 11, or 12. Each additional bit of resolution approximately doubles the conversion time. This is accomplished by programming the configuration register. The configuration register defines the conversion state, thermometer resolution/conversion time, active state of the thermostat output, number of consecutive faults to trigger an alarm condition, and the method to terminate an alarm condition. The user can also program over–temperature (TOS) and under–temperature (THYST) setpoints for thermostatic operation. The power–up state of TOS is 80 °C and that for T HYST is 75 °C. The result of each temperature conversion is compared with the TOS and THYST setpoints. The DS75 offers two modes for temperature control, the comparator mode and the interrupt mode. This allows the user the flexibility to customize the condition that would generate and clear a fault condition. Regardless of the mode chosen, the O.S. output will become active only after the measured temperature exceeds the respective trippoint a consecutive number of times; the number of consecutive conversions beyond the limit to generate an O.S. is programmable. The power–up state of the DS75 is in the comparator mode with a single fault generating an active O.S. Digital data is written to/read from the DS75 via a 2–wire interface, and all communication is MSb first. Multipoint sensing is possible with the DS75 by uniquely setting the 3–bit address of up to 8 parts on the 2–wire bus. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |