12 / 23 page ![]() ADS1253 SBAS199B 12 www.ti.com SYMBOL DESCRIPTION MIN TYP MAX UNITS tOSC CLK Period 125 ns tDRDY Conversion Cycle 384 • tOSC ns DRDY Mode DRDY Mode 36 • tOSC ns DOUT Mode DOUT Mode 348 • tOSC ns t1 DOR Write Time 6 • tOSC ns t2 DOUT/DRDY LOW Time 6 • tOSC ns t3 DOUT/DRDY HIGH Time (Prior to Data Out) 6 • tOSC ns t4 DOUT/DRDY HIGH Time (Prior to Data Ready) 24 • tOSC ns t5 Rising Edge of CLK to Falling Edge of DOUT/DRDY 30 ns t6 End of DRDY Mode to Rising Edge of First SCLK 30 ns t7 End of DRDY Mode to Data Valid (Propagation Delay) 30 ns t8 Falling Edge of SCLK to Data Valid (Hold Time) 5 ns t9 Falling Edge of SCLK to Next Data Out Valid (Propagation Delay) 30 ns t10 SCLK Setup Time for Synchronization or Power Down 30 ns t11 DOUT/DRDY Pulse for Synchronization or Power Down 3 • tOSC ns t12 Rising Edge of SCLK Until Start of Synchronization 1537 • CLK 7679 • CLK ns t13 Synchronization Time 0.5 • CLK 6143.5 • CLK ns t14 Falling Edge of CLK (After SCLK Goes LOW) Until Start of DRDY Mode 2042.5 • CLK ns t15 Rising Edge of SCLK Until Start of Power Down 7681 • CLK ns t16 Falling Edge of CLK (After SCLK Goes LOW) Until Start of DRDY Mode 2318.5 • tOSC ns t17 Falling Edge of Last DOUT/DRDY to Start of Power Down 6144.5 • tOSC ns t18 DOUT/DRDY High Time After MUX Change 2043.5 • tosc ns TABLE III. Digital Timing. TABLE IV. ADS1253 Data Format (Offset Binary Two’s Complement). DIFFERENTIAL VOLTAGE INPUT DIGITAL OUTPUT (HEX) +Full-Scale 7FFFFFH Zero 000000H –Full-Scale 800000H POWER-DOWN MODE The normal state of SCLK is LOW; however, by holding SCLK HIGH, the ADS1253 will enter power-down mode. This is accomplished by holding SCLK HIGH for at least 20 consecutive DOUT/DRDY periods (see Figure 14). After the ADS1253 circuitry detects that SCLK has been held HIGH for four consecutive DOUT/DRDY cycles, the DOUT/DRDY pin pulses LOW for one CLK cycle and then is held HIGH, and the modulator is held in a reset state. If SCLK is held HIGH for an additional 16 DOUT/DRDY periods, the ADS1253 will enter power-down mode. The part will be released from power-down mode on the falling edge of SCLK. It is impor- tant to note that the DOUT/DRDY pin is held HIGH after four DOUT/DRDY cycles, but power-down mode is not entered for an additional 16 DOUT/DRDY periods. The first DOUT/DRDY pulse after the falling edge of SCLK occurs at t16 and indicates valid data. Subsequent DOUT/DRDY pulses will occur normally. SERIAL INTERFACE The ADS1253 includes a simple serial interface that can be connected to microcontrollers and digital signal processors in a variety of ways. Communications with the ADS1253 can commence on the first detection of the DOUT/DRDY pulse after power up. It is important to note that the data from the ADS1253 is a 24-bit result transmitted MSB-first in Offset Binary Two’s Complement format, as shown in Table IV. The data must be clocked out before the ADS1253 enters DRDY mode to ensure reception of valid data, as described in the DOUT/DRDY section of this data sheet. FIGURE 11. DOUT/DRDY Partitioning. DATA DRDY Mode DOUT Mode DOUT Mode DATA DATA t 4 t 2 t 3 t 1 DRDY Mode DOUT/DRDY FIGURE 12. Multiplexer Operation. DATA DATA DOUT/DRDY t 18 MUX Change CHS0, CHS1 |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |