| 전자부품 데이터시트 검색엔진 |
|
AS5040-ASST 데이터시트(PDF) 20 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
AS5040-ASST 데이터시트(HTML) 20 Page - List of Unclassifed Manufacturers |
|
20 / 34 page ![]() AS5040 Data Sheet www.austriamicrosystems.com Revision 2.10 19 - 33 Table 6: One Time Programmable (OTP) Register Options OTP-Mode-Register-Bit Pin # Pulses per Revolution Incremental Resolution Mode Md1 Md0 Div1 Div0 Index 3 4 6 12 ppr bit Default (Mode0.0) 0 0 0* 0* 0* 1LSB quadAB-Mode1.0 0 1 0 0 0 1LSB quadAB-Mode1.1 0 1 0 0 1 3LSBs 2x256 10 quadAB-Mode1.2 0 1 0 1 0 1LSB quadAB-Mode1.3 0 1 0 1 1 3LSBs 2x128 9 quadAB-Mode1.4 0 1 1 0 0 1LSB quadAB-Mode1.5 0 1 1 0 1 3LSBs 2x64 8 quadAB-Mode1.6 0 1 1 1 0 1LSB quadAB-Mode1.7 0 1 1 1 1 A B 3LSBs PWM 10 bit 2x32 7 Step/Dir-Mode2.0 1 0 0 0 0 1LSB Step/Dir-Mode2.1 1 0 0 0 1 3LSBs 512 10 Step/Dir -Mode2.2 1 0 0 1 0 1LSB Step/Dir -Mode2.3 1 0 0 1 1 3LSBs 256 9 Step/Dir -Mode2.4 1 0 1 0 0 1LSB Step/Dir -Mode2.5 1 0 1 0 1 3LSBs 128 8 Step/Dir -Mode2.6 1 0 1 1 0 1LSB Step/Dir -Mode2.7 1 0 1 1 1 LSB Dir 3LSBs PWM 10 bit 64 7 Commutation- Mode3.0 1 1 0 0 0 10 Commutation- Mode3.1 1 1 0 1 0 U(0º) V(120º) W(240º) LSB 3 x 1 9 Commutation- Mode3.2 1 1 1 0 0 10 Commutation- Mode3.3 1 1 1 1 0 U’ (0º, 180º) V’ (60º, 240º) W’ (120º, 300º) LSB 2 x 3 9 Note: Div1, Div0 and Index cannot be programmed in Mode 0:0 Zero Position Programming Zero position programming is an OTP option that simplifies assembly of a system, as the magnet does not need to be manually adjusted to the mechanical zero position. Once the assembly is completed, the mechanical and electrical zero positions can be matched by software. Any position within a full turn can be defined as the permanent new zero/index position. For zero position programming, the magnet is turned to the mechanical zero position (e.g. the “off”-position of a rotary switch) and the actual angular value is read. This value is written into the OTP register bits Z9:Z0 (see Figure 14) and programmed as described in section 12. This new absolute zero position is also the new Index pulse position for incremental output modes. Note: The zero position value may also be modified before programming, e.g. to program an electrical zero position that is 180° (half turn) from the mechanical zero position, just add 512 to the value read at the mechanical zero position and program the new value into the OTP register. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |