| 전자부품 데이터시트 검색엔진 |
|
ILTS 데이터시트(PDF) 1 Page - Cynergy3 Co |
|
|
|||||||||||||||||||||||||||||
ILTS 데이터시트(HTML) 1 Page - Cynergy3 Co |
|
1 / 2 page ![]() www.cynergy3.com © 2014 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited. ISO 9001 CERTIFIED ILTS series Submersible Dual Level & Temperature Transmitter Cynergy3 Components Ltd. 7 Cobham Road Ferndown Industrial Estate Wimborne, Dorset BH21 7PE Telephone +44 (0) 1202 897969 Email:sales@cynergy3.com Web: www.cynergy3.com The ILTS is designed for use in continuous submersion in liquids such as water, oil and fuels. The probe uses the latest piezo- resistive media-isolated silicon sensing technology and a stainless steel diaphragm. Housed within a 316L stainless steel, or high grade Duplex stainless steel housing, this submersible transmitter is the ideal product for hydrostatic level measurement where temperature is also a critical part of the measurement. It offers excellent stability, repeatability and resolution, as required for use in rivers and reservoirs. This type incorporates a Class ‘B’ accuracy platinum resistance thermometer. Every device is temperature compensated, calibrated and supplied with a traceable serial number and calibration certificate. Level accuracy: <0.1% FS BFSL Pressure ranges from 1mWG to 10mWG Temperature range: -20 to +60ºC Custom versions can be made for particular applications. Stainless steel, piezo-resistive sensor Dual independent 4-20mA outputs Suitable applications River level & temperature Reservoir level & temperature Tank level & temperature Borehole level & temperature Aquifer level & temperature Environmental monitoring V-notch weir flow measurement Level Performance Accuracy (Non-Linearity & Hysteresis) <±0.1% / FS (BFSL) Setting Errors (offsets) Zero & Full Scale, <±0.5% / FS Permiss ble Load R = [(Voltage Supply-9)/0.02]Ohms i max Influence Effects Supply <0.005% FS / 1V Load 0.05% FSO / kOhm Temperature Performance Measurement Accuracy (mA output/2000) or 5 µA (whichever is the greater) Thermal drift 1 µA/ºC Loop Voltage effect 0.2µA/V Maximum output load [(Vsupply-10)/21] kOhms (Example: 700 Ohms @ 24V) Output Timing Transmitter start up time: 4 seconds (I out <4mA during start up) Warm up time: 1 minute to full accuracy Update time: 500ms Response time: 1 second Pressure Ranges Nominal Pressure, Gauge mWG 1 5 10 Permissible Overpressure mWG 20 50 50 Temperature Range Temperature range ºC -20 to +60 Output Signals and Supply Voltages Output Supply Voltage Connection Wire Colours +ve Supply Red Level (2-wire) 4-20mA 9-32Vdc -ve Supply Blue Ground Green & Cable Screen +ve Supply White Temperature (2-wire) 4-20mA 9-32Vdc -ve Supply Yellow Ground Green & Cable Screen |
유사한 부품 번호 - ILTS |
|
유사한 설명 - ILTS |
|
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |