18 / 21 page ![]() Recommendations AN3306 18/21 Doc ID 18182 Rev 1 8 Recommendations Because the current sensor is wound on a dielectric support, the positioning of the spires with respect to the cable has a relevant impact on performance in terms accuracy. Placing the spires of the sensor in an axial position with the cable in the middle, as shown in Figure 8, produces a higher sensitivity. Additional tests were conducted for current sensor 1, placing it in a diagonal position with respect to the current cable. Figure 10. Cable in a diagonal position The results are shown in column 4 of Table 6, and are compared to the accuracy error of the same sensor with the cable in an axial position (column 3). Table 6. Accuracy results vs. current comparison between axial and diagonal position I [A] % IN Error % - axial Error % - diagonal 10 100% 0.0000% 0.0000% 1 10% -0.0640% -0.0409% 0.5 5% -0.0040% -0.0214% 0.1 1% -0.8436% -1.0730% |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|