| 전자부품 데이터시트 검색엔진 |
|
L6206 데이터시트(PDF) 21 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L6206 데이터시트(HTML) 21 Page - STMicroelectronics |
|
21 / 53 page ![]() 21/53 AN1762 APPLICATION NOTE Figure 21. Typical disable and delay time as a function of CEN, for several values of REN. 3.13 Adjusting the Over Current Detection trip point (L6206 ONLY) The L6206 allows the user to set the Over Current Detection threshold separately for the two full bridges con- necting two resistors (RCL) to pins PROGCLA and PROGCLB. The OCD threshold (ISOVER) follows the equa- tions: –ISOVER = 5.6A ±30% at -25 °C < Tj < 125 °C if RCL = 0 Ω (PROGCL connected to GND) –ISOVER = ±10% at -25 °C < Tj < 125 °C if 5K Ω < RCL < 40k Ω Figure 22 shows the OCD threshold versus RCL value in the range from 5kΩ to 40kΩ. 11 0 1 0 0 0. 1 1 10 C EN [ nF] 11 0 1 0 0 1 10 10 0 1 . 10 3 C EN [ nF] R EN = 220 k Ω R EN = 100 k Ω R EN = 47 k Ω R EN = 33 k Ω R EN = 10 k Ω 22100 R CL ---------------- |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|