37 / 40 page ![]() AN2713 Software installation Doc ID 14431 Rev 1 37/40 If the PCL checkbox is checked, a simple output short-circuit current clamp is set. If not, the overcurrent protection circuit works dynamically: as soon as an overload is detected, the output current is provided for 90 ms (typ.), after which the output is set in shutdown for a time TOFF of 900 ms (typ). Simultaneously, the diagnostic OLF I2C bit of the system register is set high. This feature allows the reduction of the total power dissipation during an overload or a short-circuit condition: ● EN=1, PCL=1 ● Vout=13.4 Vtyp Figure 37. PCL deactivation |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|