13 / 31 page ![]() AN3172 Harmonic content measurement Doc ID 17230 Rev 1 13/31 3 Harmonic content measurement The board has been tested according to the European standard EN61000-3-2 Class-D and Japanese standard JEITA-MITI Class-D, at both the nominal input voltage mains. As shown in Figure 5 and 6, the circuit is able to reduce the harmonics well below the limits of both regulations. On the bottom side of the diagrams the total harmonic distortion and power factor have also been measured. The values in all conditions give a clear idea about the correct functioning of the PFC. Figure 5. Compliance to EN61000-3-2 at 230 Vac - 50 Hz, full load Figure 6. Compliance to JEITA-MITI at 100 Vac - 50 Hz, full load THD = 5.13 % - PF = 0.965 THD = 3.89 % - PF = 0.996 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|