24 / 37 page ![]() Feedback loop calculation guidelines AN4165 24/37 Doc ID 023661 Rev 1 11 Feedback loop calculation guidelines 11.1 Transfer function The set PWM modulator + power stage is indicated with G1(f), while C(f) is the “controller”, i.e. the network which is in charge of ensuring the stability of the system. Figure 34. Control loop block diagram The mathematical expression of the power plant G1(f) is the following: Equation 2 where VOUT is the output voltage, Ipkp is the primary peak current, fp is the frequency of the pole due to the output load: Equation 3 and fz the frequency of the zero due to the ESR of the output capacitor: Equation 4 AM11582v1 ) fp j (1 ) , ( ) fz (1 V ) p 2 j (1 ) , ( ) z 2 (1 V = I V (f) G OUT OUT pk OUT 1 f Vdc fsw Ipkp f j f Vdc fsw Ipkp f j ⋅ + ⋅ ⋅ + ⋅ = ⋅ ⋅ ⋅ + ⋅ ⋅ ⋅ ⋅ + ⋅ Δ Δ = π π 2ESR) + ·(R C 1 fp OUT OUT ⋅ = π ·ESR C 2 1 fz OUT ⋅ ⋅ = π |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|