14 / 16 page ![]() BMAX calculation for remanent induction AN441 14/16 Doc ID 3579 Rev 3 Case 2 Winding is switched on whereas a remanent negative induction remains on magnetic core. According to Equation 8, for t = 0, we have then: Equation 11 So Equation 12 So the maximum induction will be: BMAX = 2·Bn - Br Figure 12 shows the maximum induction difference between two triggering methods according to previous remanent induction. When the first half-cycle conduction is the same polarity as the previous one, the induction reaches a maximum which can be the double of the induction when triggering in reverse polarity compared to remanent induction. In the first case saturation can be reached very rapidly and the load behaves like a short circuit. The peak current is limited only by the series resistance of the load. Such phenomenon mainly occurs with transformers where the remanent induction can be very high. Figure 12. Induction at beginning of conduction according to remanent induction r n 0 r 0 n B B B B B B B(0) − = → − = + − = r B n B ) 2 ð t ·sin( ù n B B(t) − + − = ⇒ |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |