Back Button AN1709 Datasheet HTML 8Page - STMicroelectronics AN1709 Datasheet HTML 9Page - STMicroelectronics AN1709 Datasheet HTML 10Page - STMicroelectronics AN1709 Datasheet HTML 11Page - STMicroelectronics AN1709 Datasheet HTML 12Page - STMicroelectronics AN1709 Datasheet HTML 13Page - STMicroelectronics AN1709 Datasheet HTML 14Page - STMicroelectronics AN1709 Datasheet HTML 15Page - STMicroelectronics AN1709 Datasheet HTML 16Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 12 / 38 page
background image
12/38
EMC DESIGN GUIDE FOR ST MICROCONTROLLERS
Figure 6. Absolute Electrical Sensitivity test models
2.1.3.1 Human Body Model Test Sequence
The HBM ESD pulse simulates the direct transfer of electrostatic charge, from the Human
Body, to a test device. A 100pF capacitor is discharged through a switching component and a
1.5 Kohm series resistor. This is currently the most requested industry model, for classifying
device sensitivity to ESD.
– CL is loaded through S1 by the HV pulse generator.
– S1 switches position from generator to R.
– A discharge from CL through R (body resistance) to the µC occurs.
– S2 must be closed 10 to 100ms after the pulse delivery period to ensure the µC is not left in
charge state. S2 must be opened at least 10ms prior to the delivery of the next pulse.
2.1.3.2 Machine Model Test Sequence
The MM ESD pulse emulates the rapid direct transfer of electrostatic charge, from a charged
conductive object, such as a metallic tool or fixture, to a test device. This model consists of a
discharged 200pF capacitor, with no series resistor. The demand for MM ESD testing has in-
creased, with the replacement of individual packaging by automated systems.
– CL is loaded through S1 by the HV pulse generator.
– S1 switches position from generator to the µC.
– A discharge from CL to the µC occurs.
– S2 must be closed 10 to 100ms after the pulse delivery period to ensure the µC is not left in
charge state. S2 must be opened at least 10ms prior to the delivery of the next pulse.
R (machine resistance), in series with S2, ensures a slow discharge of the µC.
Table 9 shows how HBM/MM ESD test results are presented in ST datasheets.
µC
S2
R=1500W
S1
HIGH VOLTAGE
CL=100pF
PULSE
GENERATOR
µC
S2
HIGH VOLTAGE
CL=200pF
PULSE
GENERATOR
S1
HUMAN BODY MODEL
MACHINE MODEL



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com