13 / 17 page ![]() AN3248 Capacitance measurement Doc ID 17758 Rev 3 13/17 Figure 11. Capacitance measurement using COMP2 At the moment where the input voltage crosses the threshold and the COMP2 output switches to high level, the charge function is given by Equation 1. Equation 1 where “tc” is the time when the input voltage crosses the threshold Using Equation 1 the capacitance value can be computed by Equation 2. Equation 2 Usually R, the threshold, and VDD are constant, so, measuring the capacitance is reduced to solving for Equation 3. Equation 3 where K is solved using Equation 4 Equation 4 Threshold TIMx OCy Time Input voltage Time Time Capture event 0 Time COMP2 output 65535 Timer counter Capture event Capture event ai18710 Threshold VDD 1 -tc T ⁄ () exp – () = C t R 1-threshold V DD () ⁄ () ln × () ⁄ – = Ct K ⁄ – = KR 1-threshold VDD () ⁄ () ln × = |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|