| 전자부품 데이터시트 검색엔진 |
|
AN3258 데이터시트(PDF) 13 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN3258 데이터시트(HTML) 13 Page - STMicroelectronics |
|
13 / 16 page ![]() AN3258 HSI calibration Doc ID 17825 Rev 1 13/16 1.7 LIN clock deviation LIN clock deviations may be caused by the following sources: 1. Deviation due to transmitter error (DTRA): The transmitter can be either a master or a slave (in the case of a slave listening to the response of another slave). 2. Error due to the LIN synch measurement performed by the receiver (DMEAS). 3. Error due to the baud rate quantization of the receiver (DQUANT). 4. Deviation of the local oscillator of the receiver (DREC): This deviation can occur during the reception of one complete LIN message assuming that the deviation was compensated at the beginning of the message. 5. Deviation due to the transmission line (DTCL) which is generally due to the transceivers. Total clock deviation = DTRA + DMEAS + DQUANT + DREC + DTCL If the LINUART is to receive a character correctly, the total deviation should be <3.75 %. For more details, please refer to the STM8A (RM0009) and STM8S (RM0016) reference manuals. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|