14 / 24 page ![]() Temperature sensor application description AN3397 14/24 Doc ID 018809 Rev 1 Note: In any application, a user may decide to make a trade-off and use the V90 datasheet typical value and the user calibration point to obtain less accurate but nevertheless very good temperature calculation results. 2.4.3 Calibration technique The calibration technique is a one-off procedure which must be done when the STM8L- DISCOVERY is received. It consists of calculating the average slope of the TS, and is available only when the TS application Advanced mode is selected. The calibration technique makes use of Equation 5 to calculate the average slope. The factory calibration value, V90, is obtained from a fixed data address (see Advanced mode). VAMBIENT is measured during the calibration procedure. To accurately calculate the average slope, TAMBIENT must be measured using a temperature measuring device such as a thermometer. The #define Tambient must be updated with the temperature given by the thermometer. By default, TAMBIENT (which can be found in the main.c file) is set to 25 °C in the TS application code. To start the calibration procedure, press the user push-button for at least 2 s, then release the button. If calibration is successful, the message ‘CAL-OK’ is displayed on the LCD screen. If no factory calibrated value is present, or if the present value is out of range (580 mV - 614 mV), the message 'CALERR' is displayed. Press the user push-button again to continue. When calibration is successful, the value is stored in the Data EEPROM of the microcontroller. By default, the value is stored as two bytes in the Data EEPROM addresses 0x1000 (MSB) and 0x1001 (LSB). In Advanced mode, an automatic calibration is performed by the software if no calibration has been made by the user. Note: Automatic calibration may not be accurate because, by default, TAMBIENT is set to 25 °C. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |