13 / 20 page ![]() DocID024663 Rev 2 13/20 AN4299 How to improve noise immunity 19 4.2 Active Shield The Active Shield is an electrode which wraps around the sensor. The goal is to minimize the parasitic capacitance between the sensor and the ground. To drive the shield electrode, a channel of a dedicated group with its own Cs can be used. Figure 6. Active Shield It is important to check the shied electrode waveform. Cs shield capacitance value and Rs shield serial resistor value must be adjusted in order to obtain the same signal shape as sensor electrode waveform (same amplitude, same response time). Figure 7 below shows the electrode sensor waveform in green and shield electrode waveform in yellow. Cs shield is adjusted to obtain approximately the same charge level at the end of the acquisition. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|