12 / 20 page ![]() LTC1695 12 APPLICATIONS INFORMATION sistor capable of sinking 3mA at less than 0.4V during the slave acknowledge sequence. The LTC1695 is compatible with the Philips/Signetics I2C Bus Interface. The 1.4V threshold for SCL and SDA does not create any I2C application problems. Early Stop Conditions If a stop condition occurs before the data byte is acknowl- edged in the write byte protocol, the LTC1695’s DAC is not updated. Otherwise, the internal register is updated with the new data and VOUT changes accordingly to the new programmed value. Address, Command, Data Selection The LTC1695’s address is hard-wired internally as 1110100 (MSB to LSB, A6 to A0). Consult LTC for parts with alternate address codes. Consult the Address, Command and Data Byte Tables for further information and as a concise reference. As shown in Figure 2, D5 to D0 in the command code, control the linear regulator’s output voltage and thus fan speed. D5 to D0 are sent from the host to the LTC1695 during send byte protocol. The LTC1695 latches D5 to D0 as DAC input data at the falling edge of the data acknowl- edge signal. The host must set “BST” (boost start enable bit) to high if the LTC1695’s 250ms boost start timer option is used. All bits are reset to zero during power-on reset and UVLO. As shown in the Timing Diagram, bit 6 and bit 7 in the data byte register are defined as thermal shutdown status (THE) and over current fault (OCF) status respectively. The LTC1695 sets OCF high if ILOAD exceeds 390mA typically and “THE” high if junction temperature exceeds 155 °C typically. The remaining bits of the data byte’s register (bit 5 to 0) are set low during host read back. SCL and SDA SCL is the synchronizing clock signal generated by the host. SDA is the bidirectional data transfer line between the host and a slave device. The host initiates a start bit by pulling SDA from high to low while SCL is high. The stop bit is initiated by changing SDA from low to high while SCL is high. All address, command and acknowledge signals must be valid and should not change while SCL is high. The acknowledge bit signals to the host the acceptance of a correct address byte or command byte. The SCL and SDA input threshold voltages are typically 1.4V with 40mV of hysteresis. Connect the SCL and SDA open-drain lines to either a resistive or current source pull up. The LTC1695 SDA has an open-drain N-channel tran- Figure 2. SMBus Interface Bit Definition 123456789 10 11 12 13 14 15 16 17 18 19 S 111010000 X BST D5 D4 D3 D2 D1 D0 0 P 123456789 10 11 12 13 14 15 16 17 18 19 S 1110100 0 1 OCF THE 00000 0 1 P SLAVE ADDRESS S = SMBus START BIT P = SMBus STOP BIT BST = 1 ENABLES THE BOOST START TIMER D5 TO D0 = 6-BIT INPUT CODE FOR THE DAC (D5 = MSB) OCF = 1 SIGNALS THAT THE LTC1695 IS IN CURRENT LIMIT THE = 1 SIGNALS THAT THE LTC1695 IS IN THERMAL SHUTDOWN BIT 18 = 1 IS A NOT ACKNOWLEDGE FOR RECEIVE BYTE PROTOCOL NOTE: DURING POWER UP AND UVLO, DAC INPUT BITS (D5 TO D0) AND THE BST BIT ARE RESET TO ZERO COMMAND BYTE START STOP A6 A5 A4 A3 A2 A1 A0 W A MSB LSB A SLAVE ADDRESS DATA BYTE START STOP A6 A5 A4 A3 A2 A1 A0 W A A SMBus SEND BYTE PROTOCOL SMBus RECEIVE BYTE PROTOCOL 1695 • F02 |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |