19 / 164 page ![]() TLE9263QX General Product Characteristics Data Sheet 19 Rev. 1.1, 2014-09-26 Note: There is no additional current consumption contribution due to PWM generators. Current consumption for HSx in SBC Stop Mode I Stop,HSx,85 – 575 700 µA 2)3)6)SBC Stop Mode; T j = 85°C; Cyclic Sense & HSx = ON (no load); LIN, CAN, WK1..3 = OFF P_4.4.34 Current consumption for cyclic sense function I Stop,CS25 –20 26 µA 3)7)8)SBC Stop Mode; WD = OFF P_4.4.23 Current consumption for cyclic sense function I Stop,CS85 –24 35 µA 2)3)7)8)SBC Stop Mode; T j = 85°C; WD = OFF P_4.4.27 Current consumption for watchdog active in Stop Mode I Stop,WD25 –20 26 µA 2)SBC Stop Mode; Watchdog running P_4.4.30 Current consumption for watchdog active in Stop Mode I Stop,WD85 –24 35 µA 2)SBC Stop Mode; T j = 85°C; Watchdog running P_4.4.31 Current consumption for active fail outputs (FO1..3) I Stop,FOx –1.0 2.0 mA 2)all SBC Modes; T j = 25°C; FOx = ON (no load); P_4.4.24 1) If the load current on VCC1 will exceed the configured VCC1 active peak threshold IVCC1,Ipeak1,r or IVCC1,Ipeak2,r, the current consumption will increase by typ. 2.9mA to ensure optimum dynamic load behavior. Same applies to VCC2. For VCC3 the current consumption will increase by typ. 1.4mA. See also Chapter 6, Chapter 7, Chapter 8. 2) Not subject to production test, specified by design. 3) Current consumption adders of features defined for SBC Sleep Mode also apply for SBC Stop Mode and vice versa (unless otherwise specified). 4) No pull-up or pull-down configuration selected. 5) The specified WKx current consumption adder for wake capability applies regardless how many WK inputs are activated. 6) A typ. 75µA / max 125µA ( T j = 85°C) adder applies for every additionally activated HSx switch in SBC Stop Mode; In SBC Normal Mode every HSx switch consumes the typ. 75µA / max 125µA ( T j = 85°C) without the initial adder because the biasing is already enabled. 7) HS1 used for cyclic sense, Timer 2, 20ms period, 0.1ms on-time, no load on HS1. In general the current consumption adder for cyclic sense in SBC Stop Mode can be calculated with below equation: IStop,CS = 18µA + (525µA *tON/TPer) 8) Also applies to Cyclic Wake Table 4 Current Consumption (cont’d) Current consumption values are specified at Tj = 25°C, VS = 13.5V, all outputs open (unless otherwise specified) Parameter Symbol Values Unit Note / Test Condition Number Min. Typ. Max. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |