| 전자부품 데이터시트 검색엔진 |
|
CS1124 데이터시트(PDF) 5 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
CS1124 데이터시트(HTML) 5 Page - ON Semiconductor |
|
5 / 8 page ![]() CS1124 http://onsemi.com 5 CIRCUIT DESCRIPTION Figure 3 shows the part operating near the minimum input thresholds. As the sin wave input threshold is increased, the low side clamps become active (Figure 4). Increasing the amplitude further (Figure 5), the high−side clamp becomes active. These internal clamps allow for voltages up to −250 V and 250 V on the sensor side of the setup (with R1 = R2 = 22 k) (reference the diagram page 1). Figure 6 shows the effect using the diagnostic (DIAG) function has on the circuit. The input threshold (negative) is switched from a threshold of −160 mV to +160 mV when DIAG goes from a low to a high. There is no hysteresis when DIAG is high. Figure 3. Minimum Threshold Operation IN1, 200 mV/div OUT1, 2.0 V/div 20 ms/div Figure 4. Low−Side Clamp IN1, 5.0 V/div OUT1, 2.0 V/div 20 ms/div Figure 5. Low− and High−Side Clamps IN1, 5.0 V/div OUT1, 2.0 V/div 20 ms/div Figure 6. Diagnostic Operation DIAG 5.0 V/div 20 ms/div IN1 1.0 V/div OUT1 5.0 V/div |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |