| 전자부품 데이터시트 검색엔진 |
|
AN607 데이터시트(PDF) 28 Page - Silicon Laboratories |
|
|
|||||||||||||||||||||||||||||
AN607 데이터시트(HTML) 28 Page - Silicon Laboratories |
|
28 / 41 page ![]() AN607 28 Rev. 1.7 Equation Comparison The following graph compares the above equations: Mark Lawrence Rule of Thumb* This easy to use equation provides an estimate of change in dew point for a change in relative humidity or can be easily reversed to estimate a change in relative humidity for a known change in dew point. This approximation is valid for RH>50%. This rule of thumb says that the dew point temperature decreases approximately 1C for every 5% decrease in RH starting at tdp = t and RH=100%. This relationship is very handy if very little computational capability is available and the accuracy limitations and range of applicability are acceptable. *Note: See Lawrence, Mark G., “The Relationship between Relative Humidity and the Dewpoint Temperature in Moist Air - A Simple Conversion and Applications”, American Meteorological Society February 2005. Td B 1 In RH 100 ---------- A 1T B 1 T + ---------------- + A 1 In RH 100 ---------- – A 1T B 1 T + ---------------- – --------------------------------------------------------- = |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|