전자부품 데이터시트 검색엔진
  Korean  ▼
ALLDATASHEET.CO.KR

X  

SP2525 데이터시트(PDF) 4 Page - Sipex Corporation

부품명 SP2525
상세설명  3.0V to 5.5V USB Power Control Switch
PDF  16 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  SIPEX [Sipex Corporation]
홈페이지  http://www.sipex.com
Logo SIPEX - Sipex Corporation

SP2525 데이터시트(HTML) 4 Page - Sipex Corporation

  SP2525 Datasheet HTML 1Page - Sipex Corporation SP2525 Datasheet HTML 2Page - Sipex Corporation SP2525 Datasheet HTML 3Page - Sipex Corporation SP2525 Datasheet HTML 4Page - Sipex Corporation SP2525 Datasheet HTML 5Page - Sipex Corporation SP2525 Datasheet HTML 6Page - Sipex Corporation SP2525 Datasheet HTML 7Page - Sipex Corporation SP2525 Datasheet HTML 8Page - Sipex Corporation SP2525 Datasheet HTML 9Page - Sipex Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 4 / 16 page
background image
4
Rev. 8/21/01
SP2525 +3.0 to +5.5 Power Control Switch
© Copyright 2001 Sipex Corporation
FEATURES
The SP2525 device is a single +3.0V to +5.5V
USB Supervisory Power Control Switch ideal
for self-powered and bus-powered Universal
Serial Bus (USB) applications. USB provides
a +5.0V bus and ground return line in addition
to a twisted pair line for data.
Features of the SP2525 device include current
limiting, a +2.7V undervoltage lockout, over-
temperature shutdown, error flag output, soft
start power up, a switch-on resistance of 140m
over the entire supply range, and a supply
current of 80
µA. The SP2525-1 device has
active-high inputs. The SP2525-2 device has
active-low inputs.
THEORY OF OPERATION
There are operational conditions that will en-
able or disable one or more of the output
transistors, depending on the type of hazard.
Certain conditions will activate the open-drain
error flag transistors forcing the flag output to
ground. The SP2525 device is a single inte-
grated high-side power switch optimized for
self-powered and bus-powered Universal Se-
rial Bus (USB) applications. The SP2525 de-
vice provides the following functions:
1) Solid State Switch : MOSFET M1 connects
the IN pin to the OUT pins when enabled by a
logic signal at the EN pin.
2) Fault Flag Conditions : The FLG pin is an
N-channel, open-drain MOSFET output ca-
pable of sinking a 10mA load to typically
100mV above ground.
3) Undervoltage Lockout : The lockout mecha-
nism monitors the input voltage and will enable
the MOSFET switch only when the input sig-
nal is >2.7V.
4) Current Limiting Threshold : A current
limiting threshold is set internally to prevent
any damage to the device and external load.
5) Thermal Shutdown : This mechanism pro-
tects the device switch and signals a fault condi-
tion if the die temperature exceeds 135OC. This
function has 10OC of hysteresis that prevents the
MOSFET switches from turning on until the die
temperature drops to 125OC.
Input and Output
The independent solid state switch connects the
IN pin to the OUT pin when enabled by a logic
signal at EN. The IN pin is the power supply
connection to the internal circuitry and the drain
of the output MOSFET. The OUT pin is the
source of the MOSFET.
Typically, the current in USB application will
flow through the switch from IN to OUT towards
the load. If V
OUT is greater than VIN when a switch
is enabled, the current will flow from OUT to the
IN pin because the MOSFET channels are bidi-
rectional when switched on.
Under normal operating conditions, the MOSFET
switch will present 140m
Ω maximum resistance
when closed. The device is designed to allow
out pin to be externally forced to a higher voltage
than the IN pin when the switch is off.
Fault Flag Conditions
The fault flag is an N-channel, open drain
MOSFET output. The active low fault flag is
asserted when one of the following conditions
exist:
1. Undervoltage
2. Soft Start
3. Overcurrent
4. Overtemperature
Undervoltage Lockout
This voltage lockout mechanism prevents the
output MOSFET switches from turning on until
V
IN is >2.7V.
After the switch turns on, if the voltage at V
IN
drops below +2.5V, the lockout circuitry shuts
off the output MOSFET switch and signals the
FLG fault flag. In the undervoltage lockout
state, the FLG pin will be at a logic low. This
detection functions only when the MOSFET
switch is enabled.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com