전자부품 데이터시트 검색엔진
  Korean  ▼
ALLDATASHEET.CO.KR

X  

AS5170 데이터시트(PDF) 29 Page - ams AG

부품명 AS5170
상세설명  Accurate angle measurement
PDF  47 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  AMSCO [ams AG]
홈페이지  http://www.ams.com
Logo AMSCO - ams AG

AS5170 데이터시트(HTML) 29 Page - ams AG

Back Button AS5170 Datasheet HTML 25Page - ams AG AS5170 Datasheet HTML 26Page - ams AG AS5170 Datasheet HTML 27Page - ams AG AS5170 Datasheet HTML 28Page - ams AG AS5170 Datasheet HTML 29Page - ams AG AS5170 Datasheet HTML 30Page - ams AG AS5170 Datasheet HTML 31Page - ams AG AS5170 Datasheet HTML 32Page - ams AG AS5170 Datasheet HTML 33Page - ams AG Next Button
Zoom Inzoom in Zoom Outzoom out
 29 / 47 page
background image
ams Datasheet
Page 29
[v1-01] 2016-Apr-11
Document Feedback
AS5170 − Register Description
Diagnostic
AS5170A/AS5170B can be used in safety critical applications.
For this reason,AS5170A/AS5170B is developed as SEooC
(Safety element out of context) according the ISO26262.
The assumption of use (AoU) and the robust embedded
self-diagnostic, to achieve a high ASIL level in the application.
For additional information regarding the ISO26262 flow at ams
and the SEooC relevant documents (e.g. FMEDA, safety manual,)
please contact the ams technical support for magnetic position
sensors.
Figure 38:
Diagnostic Table
SM
Safety Mechanism
Recoverable
Safe State
SM1
Watchdog failure
No, if a watchdog error is detected, the
sensor provides the error information
till a sensor reset happens
Output is going into HIZ -->
failure band (depending on
output resistor)
SM2
Offset compensation
not complete
Yes, if the offset is below the specified
threshold, sensor recovers the output
Output is forced in failure band.
Depending on FBS setting
SM3
CORDIC overflow
Yes, if the magnetic input field is below
the specified threshold, sensor
recovers the output
Output is forced in failure band.
Depending on FBS setting
SM4
Magnetic input field
too high/too low
Yes, if the magnetic field is inside the
specific range, after the recovery time
the sensor leave the failure
Output is forced in failure band.
Depending on FBS setting
SM5
Vreg undervoltage
Yes
Hi-z: Failure band related to the
out load
SM6
Reverse polarity
Yes, if reverse polarity issue is solved.
No direct safety mechanism, it’s a
protection!
Hi-z: Failure band related to the
out load
SM7
VDD overvoltage
Yes, if the VDD is below the specified
threshold.
Hi-z: Failure band related to the
out load
SM8
VDD undervoltage
Yes, if the VDD is above the specified
threshold
Hi-z: Failure band related to the
out load
SM9
Broken VDD
Yes
Hi-z: Failure band related to the
out load
SM10
ADC check
No, sensor stays in failure band till the
Sensor is resetting.
Hi-z: Failure band related to the
out load
SM11
Analog read fail
Yes
Hi-z: Failure band related to the
out load
SM12
Short circuit
Yes
Hi-z: Failure band related to the
out load



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com