| 전자부품 데이터시트 검색엔진 |
|
MB39C831 데이터시트(PDF) 13 Page - Cypress Semiconductor |
|
|
|||||||||||||||||||||||||||||
MB39C831 데이터시트(HTML) 13 Page - Cypress Semiconductor |
|
13 / 40 page ![]() Document Number: 002-08404 Rev *A Page 13 of 40 MB39C831 MPPT Operation When setting the charge mode, the internal pulse frequency is determined by the values of the capacitors C5/C6 and C7/C8 (see Figure 3-1), which are connected to the CSH1 pin, and the CSH2 pin. During the period of high level of the internal pulse setting by the capacitors C5/C6 connected to the CHS1 pin, the release voltage is measured. The capacitors C5/C6 latch the measured voltage level, the release voltage. During the period of low level of the internal pulse setting by the capacitors C7/C8 connected to the CSH2 pin, the charge current is determined in order to make the VDD pin's voltage equal to the MPPT setting voltage, then the charging operation starts up. The MPPT setting voltage is calculated by the following equation. (refer to Table 7-3 MPPT control) When using the recommended pars, the frequency is set to 0.35Hz with 5% duty. If not using the recommended parts, please be aware of the following points. 1. ・In general, laminated capacitances have leak current. If the inside pulse cycle setting by the capacitors 2. C7/C8 were set too long, the voltage level of the capacitors C5/C6 would drop. There is a possibility that 3. the MPPT value cannot be set correctly. 4. ・If the period of high level of inside pulse is set too short, setting by the capacitors C5/C6, the MPPT value 5. cannot be set correctly due to a lack of the measurement time of the release voltage. Figure 7-4 MPPT Operation LX waveform Charging Operation Measurement of release voltage No DC/DC operation VDD pin voltage VOUT pin voltage Release voltage Frequency 0.35Hz Duty 5%, when using recommended parts Chareging resume Full charge detection The period of high level is set by capacitors C5 and C6. MPPT setting voltage The period of high level is set by capacitors C7 and C8. time Internal Pulse |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |