| 전자부품 데이터시트 검색엔진 |
|
TM8LR64JFN 데이터시트(PDF) 8 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TM8LR64JFN 데이터시트(HTML) 8 Page - Texas Instruments |
|
8 / 17 page ![]() TM8LR64JFN 8 388 608 BY 64BIT TM16LR64JFN 16 777 216 BY 64BIT SYNCHRONOUS DYNAMIC RAM MODULES SMMS710 − MAY 1998 8 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 ac timing requirements†‡ ’xLR64JFN-8 ’xLR64JFN-8A UNIT MIN MAX MIN MAX UNIT tCK2 Cycle time, CK CAS latency = 2 10 15 ns tCK3 Cycle time, CK CAS latency = 3 8 8 ns tCH Pulse duration, CK high 3 3 ns tCL Pulse duraction, CK low 3 3 ns tAC2 Access time, CK high to data out (see Note 11) CAS latency = 2 6 7.5 ns tAC3 Access time, CK high to data out (see Note 11) CAS latency = 3 6 6 ns tOH Hold time, CK high to data out with 50-pF load 3 3 ns tLZ Delay time, CK high to DQ in low-impedance state (see Note 12) 1 1 ns tHZ Delay time, CK high to DQ in high-impedance state (see Note 13) 8 8 ns tIS Setup time, address, control, and data input 2 2 ns tIH Hold time, address, control, and data input 1 1 ns tIH Hold time, address, control, and data input 1 1 ns tCESP Power down/self-refresh exit time 8 8 ns tRAS Delay time, ACTV command to DEAC or DCAB command 48 100 000 48 100 000 ns tRC Delay time, ACTV, MRS, REFR, or SLFR to ACTV, MRS, REFR, or SLFR command 68 68 ns tRCD Delay time, ACTV command to READ, READ-P, WRT, or WRT-P command (see Note 14) 20 20 ns tRP Delay time, DEAC or DCAB command to ACTV, MRS, REFR, or SLFR command 20 20 ns tRRD Delay time, ACTV command in one bank to ACTV command in the other bank 16 16 ns tRSA Delay time, MRS command to ACTV, MRS, REFR, or SLFR command 16 16 ns tAPR Final data out of READ-P operation to ACTV, MRS, SLFR, or REFR command tRP −(CL−1) * tCK tRP − (CL−1) * tCK ns tAPW Final data in of WRT-P operation to ACTV, MRS, SLFR, or REFR command tRP + 1 tCK tRP + 1 tCK ns tT Transition time 1 5 1 5 ms tREF Refresh interval 64 64 ms tREF Refresh interval 64 64 ms nCCD Delay time, READ or WRT command to an interrupting command 1 1 cycles nCCD Delay time, READ or WRT command to an interrupting command 1 1 cycles nCDD Delay time, CS low or high to input enabled or inhibited 0 0 0 0 cycles nCLE Delay time, CKE high or low to CLK enabled or disabled 1 1 1 1 cycles nCWL Delay time, final data in of WRT operation to READ, READ-P, WRT, or WRT-P 1 1 cycles nDID Delay time, ENBL or MASK command to enabled or masked data in 0 0 0 0 cycles nDOD Delay time, ENBL or MASK command to enabled or masked data out 2 2 2 2 cycles nHZP2 Delay time, DEAC or DCAB command to DQ in high-impedance state CAS latency = 2 2 2 cycles † All references are made to the rising transition of CK unless otherwise noted. ‡ Specifications in this table represent a single SDRAM device. NOTES: 11. tAC is referenced from the rising transition of CK that precedes the data-out cycle. For example, the first data out tAC is referenced from the rising transition of CK that is read latency (one cycle after the READ command). Access time is measured at output reference level 1.4 V. 12. tLZ is measured from the rising transition of CK that is read latency (one cycle after the READ command). 13. tHZ (max) defines the time at which the outputs are no longer driven and is not referenced to output voltage levels. 14. For read or write operations with automatic deactivate, tRCD must be set to satisfy minimum tRAS. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |