| 전자부품 데이터시트 검색엔진 |
|
HCEM010B 데이터시트(PDF) 2 Page - Sensortechnics GmbH |
|
|
|||||||||||||||||||||||||||||
HCEM010B 데이터시트(HTML) 2 Page - Sensortechnics GmbH |
|
2 / 11 page ![]() HCE Series Miniature amplified pressure sensors 2/11 E / 11652 / F www.first-sensor.com www.sensortechnics.com PRESSURE SENSOR CHARACTERISTICS (T A = 25 °C) . o n t r a Pe r u s s e r p g n i t a r e p Oe r u s s e r p f o o r P 5 , 3 e r u s s e r p t s r u B 5 , 4 . . . B . . . 0 1 0 M E C Hr a b m 0 1 ± . . . 0r a b m 0 5 2r a b m 0 0 5 . . . B . . . 0 2 0 M E C Hr a b m 0 2 ± . . . 0r a b m 0 0 5r a b m 0 5 7 . . . B . . . 0 5 0 M E C Hr a b m 0 5 ± . . . 0r a b m 0 5 7r a b 2 . 1 . . . B . . . 0 0 1 M E C Hr a b m 0 0 1 ± . . . 0r a b 2 . 1r a b 2 . . . B . . . 0 0 2 M E C Hr a b m 0 0 2 ± . . . 0r a b 2r a b 2 . . . B . . . 0 0 5 M E C Hr a b m 0 0 5 ± . . . 0r a b 2r a b 2 . . . B . . . 1 0 0 B E C Hr a b 1 ± . . . 0r a b 3r a b 5 . . . U . . . 0 1 0 M E C Hr a b m 0 1 . . . 0r a b m 0 5 2r a b m 0 0 5 . . . U . . . 0 2 0 M E C Hr a b m 0 2 . . . 0r a b m 0 0 5r a b m 0 5 7 . . . U . . . 0 5 0 M E C Hr a b m 0 5 . . . 0r a b m 0 5 7r a b 2 . 1 . . . U . . . 0 0 1 M E C Hr a b m 0 0 1 . . . 0r a b 2 . 1r a b 2 . . . U . . . 0 0 2 M E C Hr a b m 0 0 2 . . . 0r a b 2r a b 2 . . . U . . . 0 0 5 M E C Hr a b m 0 0 5 . . . 0r a b 2r a b 2 . . . U . . . 1 0 0 B E C Hr a b 1 . . . 0r a b 3r a b 5 . . . U . . . 2 0 0 B E C Hr a b 2 . . . 0r a b 6r a b 7 . . . U . . . 5 0 0 B E C Hr a b 5 . . . 0r a b 7r a b 7 . . . R A 1 1 6 0 E C H) a ( r a b m 0 0 1 1 . . . 0 0 6r a b 3r a b 5 . . . R A 1 1 8 0 E C H) a ( r a b m 0 0 1 1 . . . 0 0 8r a b 3r a b 5 Specification notes: 1. Total accuracy is the combined error from offset and span calibration, linearity, pressure hysteresis, and temperature effects. Linearity is the measured deviation based on a straight line. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. Calibration errors include the deviation of offset and full scale from nominal values. 2. Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified pressure. 3. Proof pressure is the maximum pressure which may be applied without causing durable shifts of the electrical parameters of the sensing element. 4. Burst pressure is the maximum pressure which may be applied without causing damage to the sensing element or leaks to the housing. 5. The HCE common mode pressure is 2 bar for all devices up to 500 mbar and 7 bar for all other devices. Common mode pressure is the maximum pressure that can be applied to both ports of a differential pressure sensor simultaneously without damaging the sensor housing. 6. Extended temperature ranges on request. Please contact First Sensor. 7. Max. delay time between pressure change at the pressure die and signal change at the output. 8. The response time depends on the adjusted internal A/D resolution of the sensor. For 14 bit it is typ. 1 ms. Other A/D resolutions and reponse times are available on request. Please contact First Sensor for further information. 9. Sensors with lower current consumption are available on request. Please contact First Sensor for further information. Other pressure ranges are available on request. Please contact First Sensor. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |