27 / 33 page ![]() DocID026333 Rev 4 27/33 HTS221 Humidity and temperature data conversion 33 Step 1: Temperature conversion from ADC_OUT (LSB) to °C Data to build the Temperature calibration curve are stored in device registers. Linear interpolation (example) Figure 9. Step 1: Linear interpolation to convert LSB to °C Conclusion: current temperature is 15 °C. Input temperature LSB (ADC) Output temperature (°C) T0_OUT = 300 (Msb T0_degC U T0_degC)_x8 = 80 °C => 80/8 = 10.0°C T1_OUT = 500 (Msb T1_degC U T1_degC)_x8 = 160 °C => 160/8 = 20.0°C Temperature conversion: T_OUT = 400 T_degC_x8 =120 °C =>T_degC=120/8 = 15.0 °C |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|