  X.FL-R-SMT-1 Datasheet HTML 1Page - Hirose Electric X.FL-R-SMT-1 Datasheet HTML 2Page - Hirose Electric X.FL-R-SMT-1 Datasheet HTML 3Page - Hirose Electric X.FL-R-SMT-1 Datasheet HTML 4Page - Hirose Electric X.FL-R-SMT-1 Datasheet HTML 5Page - Hirose Electric X.FL-R-SMT-1 Datasheet HTML 6Page - Hirose Electric X.FL-R-SMT-1 Datasheet HTML 7Page - Hirose Electric X.FL-R-SMT-1 Datasheet HTML 8Page - Hirose Electric  
Zoom Inzoom in Zoom Outzoom out
 6 / 8 page
background image
6
X.FL Series●Low-Profile, Ultraminiature Lightweight SMT Coaxial Connectors - 0.94 or 1.2 mm Mated Height
BUsage Precautions
1. Plugs
(1) Mating / un-mating
1.To un-mate a connector, use the unmating side of the plug mating and unmating tool
X.FL-LP-IN.OUT1 as shown in the following figure.
[How to un-mate a plug]
Insert the tool
from the direction
of the cable so that
it can hold the cable.
Tilt the tool to
pull the cable
side up.
Un-mating is completed.
Never un-mate the plug by pulling the cable. It may cause a failure of the connector.
2. To mate a connector, use the mating side of the plug mating and unmating tool X.FL-LP-
IN.OUT1 or the plug mating tool W.FL-LP-IN. Align the mating axes between both of the
connectors and check that the shell is properly aligned. The connector should be inserted
perpendicularly as much as possible. (See the following figure)
Do not attempt to insert the connector at an extreme angle. It may cause the connector to fail.
X.FL Plug Connector
X.FL-R-SMT-1 (Receptacle)
(2) Allowable load to a
cable that is mated
After the connector is mated, do not apply a load to the cable in excess of the values
indicated in the figure below.
X.FL-R-SMT-1
2 N or less (X.FL-LP-040.X.FL-LP(P)-068)
1 N or less (X.FL-LP-032)
(while wiring after mating)
When the cable is routed in such a direction that lifts the cable, it is recommended that
cushioning should be placed on the plug to prevent the connector from unmating (see the
example below).
Cushioning
(3) Precautions
Do not mate or unmate a connector with an excessive prying force. It may cause a failure of
the connector.



Html Pages

1 2 3 4 5 6 7 8


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com