34 / 64 page ![]() 3-21 3.6.5 Determination of Activation Pause Time and Activation Pulse Period Dot lines may be activated in succession to the same thermal dot in order to protect thermal head elements. Determine the activation period (the time from the preceding activation start to the current activation start) which conforms to equation (7) to reserve the pause time. Equation (7): W > t + 0.5(ms) W : Activation period of 1-dot line (ms) 3.6.6 Head Activation Pulse Term Coefficient Make adjustments using the head activation pulse term coefficient (equal motor drive frequency) as the printing density changes by the printing speed. According to equations (8), calculate compensation coefficient C of the heat pulse. Equation (8): C = 1 - 2.6/(5.0 + w) w = 2000 / motor drive frequency |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|