| 전자부품 데이터시트 검색엔진 |
|
AND8019D 데이터시트(PDF) 2 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
AND8019D 데이터시트(HTML) 2 Page - ON Semiconductor |
|
2 / 12 page ![]() AND8019/D http://onsemi.com 2 Manufacturers Contact Data Mfr. Phone Web ON Semiconductor 800 282–9855 www.onsemi.com Cooper Electronics 561 752–5000 www.cooperet.com TDK 847 803–6100 www.component.tdk.com Mallory 317 273–0090 www.nacc–doesit.com Vishay/... 818 781–1642 www.vishay.com/index.html Lumex 847 359–2790 www.lumex.com Beau Interconnect 603 524–5101 www.beauint.com Panasonic – www.panasonic.com Board Evaluation The following Power Supply Test Setup diagram and description is designed to allow the board to be tested for all parameters listed in the Converter Test Data table. This may be used to confirm proper operation of the board, as well as operating parameters of modified boards. Volt or Watt Meter 85 vac–265 vac 50 Hz–60 Hz Scope UUT Load Fixture 500 mA 90 mA 1A V 55 W 12 W 10 W Figure 1. Power Supply Test Setup Test Setup The input power source needs to be variable over the range of voltages and frequencies that you choose to test. This can be either a variac or an electronic power source. Connect it to a voltmeter or wattmeter. A wattmeter will be required to measure efficiency. If none is available, use a voltmeter. The output of the meter will be fed into the input connector on the board. The polarity is not important as this converter has an isolated output. Please keep in mind that the input side of this circuit is hot – including the ground. The output connector should be connected to an ammeter in the high line, and then to a set of load resistors. The 12 W and 10 W resistors should be rated at 10 watts, and the 55 W at 2.0 watts. Any lab scope with at least a 20 MHz bandwidth will be adequate to observe ripple and switching waveforms. The unit will not be damaged by input voltages below 85 volts, but may not operate properly. Do not exceed the 265 volt rating as this could damage the NCP1000 as well as other components. Measurement Techniques To accurately measure the output voltage and ripple, the voltmeter and oscilloscope probes should be connected as close as possible to the output terminals of the board. Measuring the output voltage at the load resistors will result in errors due to the impedance of the ammeter and of the lead wires. Ripple measurements often contain large amounts of common mode noise. Before taking measurements, connect the scope probe to the ground lead at the negative output terminal. Any spikes that are on the screen of the scope are common mode noise that is being picked up by the scope leads, and are not part of the output ripple. This phenomenon may be reduced by using two scope probes in a differential measurement mode. Connect both ground leads to the negative output terminal. Connect one scope probe to the negative terminal also, and the other to the positive terminal. Set the scope up to subtract the ground signal from the ripple signal, and the resulting waveform will be a more accurate representation of the ripple. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |