15 / 20 page ![]() DocID029495 Rev 1 15/20 SRK2001A Operation description 20 7.6.1 EN pin remote on-off During the run mode, the EN pin can be used as remote on-off input, using a small signal transistor connected to the pin. When the switch is closed, the pin voltage goes below the VEN_OFF threshold; the controller stops operating and enters a low consumption state. Then it resumes operation when the switch is opened and the pin voltage surpasses the VEN_ON threshold (thanks to an internal pull-up of 20 µA, reduced to 6 µA in run mode, IEN_run). 7.6.2 Burst-mode detection Normally, at reduced loads, resonant converters enter the burst-mode operation in order to increase converter efficiency. The SRK2001A detects that the primary controller has stopped switching, and enters the low consumption state: this happens when both DVS1,2 signals are sensed above the arming voltage VTH_A for at least 20 µs. 7.6.3 Low consumption state exit After the primary controller restarts switching or the EN pin goes back high, the controller resumes the operation when it detects that the conduction duty-cycle has increased above the value DON programmed by the user through a proper choice of the RPG resistor. The number of clock cycles needed to exit the burst-mode is proportional to the difference between the body diode conduction duty-cycle and the programmed DON threshold: this allows a faster sleep-out in case of the heavy load transient low-to-high. After recognized that the conduction duty-cycle is longer than the programmed DON, 12 switching cycles (i.e. 24 clock cycles) are still needed before the SRK2001A restarts driving the SR MOSFETs (in order to allow the settlement of the internal timers, lost during the low consumption state, where most of internal circuitry was not supplied or turned off). For the correct operation of the SRK2001A, the primary controller has to be programmed in such a way that, when it enters the burst-mode operation, the minimum switching stop has to be longer than 20 µs (necessary to the SRK2001A to detect that operating condition). Table 6. Burst-mode exiting lookup table DON RPG 80% RPG = 0 75% RPG = 100 k 65% RPG = 180 k 0% RPG open |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |