| 전자부품 데이터시트 검색엔진 |
|
TNETX3150A 데이터시트(PDF) 19 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TNETX3150A 데이터시트(HTML) 19 Page - Texas Instruments |
|
19 / 78 page ![]() TNETX15AE ADDRESS-LOOKUP DEVICE SPWS041A – AUGUST 1997 – REVISED OCTOBER 1997 19 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 unknown multicast port-routing register, unkmultiports at 0x06–0x07 (DIO) BYTE 1 BYTE 0 BIT 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Reserved Unkmultiports Initial values after reset 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 The unkmultiports register is used to route multicast frames whose multicast address is not found within the lookup table. Normally these frames are flooded to all ports except to the port that originated the frame. The TNETX15AE uses the unkmultiports register to route these frames to only selected ports. When the TNETX15AE uses the unkmultiports register for multicast flooding, it increments the unkmultictr counter. The TNETX15AE masks out the originating port when using this register. This prevents the attached switch from forwarding the frame to its originating port. The bit numbers in this register have a one-to-one correspondence with the attached switch-device port number. This register is readable/writeable and is auto-loaded from the EEPROM when the RESET terminal is asserted low or when LOAD in the control register is set. mode control status register, control at 0x08–0x09 (DIO) BYTE 1 BYTE 0 BIT 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 RESET LOAD START INITD NEEPM NAUTO Reserved NLRN0 NCRC Reserved Initial values after reset 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 No EEPROM detected 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 Auto loading fails 1 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 The control register is automatically loaded from the EEPROM when the RESET terminal is asserted low, or when the LOAD bit is set. Only selected bits in this register are loaded from the EEPROM. RESET and LOAD bits are not loaded to prevent automatic loading loops. The two status bits, INITD and NEEPM, also are not loadable. If automatic loading fails due to EEPROM malfunction or CRC error, the control register RESET bit is set. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |