13 / 18 page ![]() SPEC-1654 (REV. 4) 13/18 29-09-2017 SA4104A / SA4104B Direction Indicator Output (DIRO) The direction of the energy flow may be ascertained by monitoring the DIRO pin. A low level on this pin indicates negative energy flow. Positive energy flow is indicated by a high level. Should the energy (either negative or positive) be less than the anti-creep threshold then this output will retain its previous state. This prevents a flickering output in the case of no or very low current flow. The DIRO pin may be used to drive an LED. The state of the DIRO pin is updated on the internal FAST mode pulses, regardless of whether the device is set to FAST or STANDARD mode. A power-on reset will set DIRO high and it will remain high until negative energy above the anti-creep threshold is detected. Table 4 illustrates the operation of the DIRO output. Table 4: Operation of the DIRO output Energy Level |Phase Angle| State of DIRO < FMIN 0º - 360º Previous State > FMIN < 90º HIGH > FMIN > 90º LOW Note: FMIN is the anti-creep threshold |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|