74 / 80 page ![]() ADAS1000/ADAS1000-1/ADAS1000-2 Data Sheet EXAMPLES OF INTERFACING TO THE ADAS1000 The following examples shows register commands required to configure the ADAS1000 device into particular modes of operation and to start framing ECG data. Example 1: Initialize the ADAS1000 for ECG Capture and Start Streaming Data 1. Write 1 configures the CMREFCTL register for CM = WCT = (LA + LL + RA)/3; RLD is enabled onto the RLD_OUT electrode. The shield amplifier is enabled. 2. Write 2 configures the FRMCTL register to output nine words per frame/packet. The frame/packet of words consist of the header, five ECG words, pace, respiration magnitude, and lead-off. The frame is configured to always send, irrespective of ready status. The ADAS1000 is in analog lead format mode with a data rate of 2 kHz. 3. Write 3 addresses the ECGCTL register, enabling all channels into a gain of 1.4, low noise mode, and differen- tial input, which configures the device for analog lead mode. This register also configures the device as a master, using the external crystal as the input source to the XTALx pins. The ADAS1000 is also put into conversion mode in this write. 4. Write 4 issues the read command to start putting the converted data out on the SDO pin. 5. Continue to issue SCLK cycles to read the converted data at the configured packet data rate (2 kHz). The SDI input must be held low when reading back the conversion data because any commands issued to the interface during read of frame/packet are understood to be a change of configu- ration data and stop the ADC conversions to allow the interface to process the new command. Example 2: Enable Respiration and Stream Conversion Data 1. Write 1 configures the RESPCTL register with a 56 kHz respiration drive signal, gain = 1, driving out through the respiration capacitors and measuring on Lead I. 2. Write 2 issues the read command to start putting the converted data out on the SDO pin. 3. Continue to issue SCLK cycles to read the converted data at the configured packet data rate. 4. Note that this example assumes that the FRMCTL register has already been configured such that the respiration magnitude is available in the data frame, as arranged in Write 2 of Example 1. Example 3: DC Lead-Off and Stream Conversion Data 1. Write 1 configures the LOFFCTL register with a dc lead-off enabled for a lead-off current of 50 nA. 2. Write 2 issues the read command to start putting the converted data out on the SDO pin. 3. Continue to issue SCLK cycles to read the converted data at the configured packet data rate. 4. Note that this example assumes that the FRMCTL register has already been configured such that the dc lead-off word is available in the data frame, as arranged in Write 2 of Example 1. Table 56. Example 1: Initialize the ADAS1000 for ECG Capture and Start Streaming Data Write Command Register Addressed Read/Write Bit Register Address Data 32-Bit Write Command Write 1 CMREFCTL 1 000 0101 1110 0000 0000 0000 0000 1011 0x85E0000B Write 2 FRMCTL 1 000 1010 0000 0111 1001 0110 0000 0000 0x8A079600 Write 3 ECGCTL 1 000 0001 1111 1000 0000 0100 1010 1110 0x81F804AE Write 4 FRAMES 0 100 0000 0000 0000 0000 0000 0000 0000 0x40000000 Table 57. Example 2: Enable Respiration and Stream Conversion Data Write Command Register Addressed Read/Write Bit Register Address Data 32-Bit Write Command Write 1 RESPCTL 1 000 0011 0000 0000 0010 0000 1001 1001 0x83002099 Write 2 FRAMES 0 100 0000 0000 0000 0000 0000 0000 0000 0x40000000 Table 58. Example 3: Enable DC Lead-Off and Stream Conversion Data Write Command Register addressed Read/Write Bit Register Address Data 32-Bit Write Command Write 1 LOFFCTL 1 000 0010 0000 0000 0000 0000 0001 0101 0x82000015 Write 2 FRAMES 0 100 0000 0000 0000 0000 0000 0000 0000 0x40000000 Rev. B | Page 74 of 80 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |