| 전자부품 데이터시트 검색엔진 |
|
AS39513 데이터시트(PDF) 56 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS39513 데이터시트(HTML) 56 Page - ams AG |
|
56 / 108 page ![]() Page 56 ams Datasheet Document Feedback [v1-10] 2018-Apr-25 AS39513 − Detailed Description DIMD[1:0] – Input mode for DIN pin (when not in SPI communication). 2’b00 = CMOS input, non-inverting 100k ohm pull down to ground enabled. 2’b01 = Digital sensor input with pull up. Pull-up current is supplied to DIN only during a logging event. 2’b10 = Use the DIN pin for startup. When in the WAIT state, a pull-up current is supplied to DIN. A falling edge on DIN manually causes a transition from WAIT mode to ACTIVE mode. If TMSRT is also 1, the event that happens first (delay or DIN input) causes the transition from WAIT mode to ACTIVE mode. 2’b11 = Use the DIN pin for a logging interrupt. During ACTIVE mode, a pull-up current is supplied to DIN. A falling edge on DIN generates a logging event. DLOG – Add the digital input and external sensor interrupt values to the data that is logged. The two-bit value { din_i, extirq_i } is added to the logging data. 0 = No status logging of the digital input and external sensor interrupt. 1 = Add logging of the digital input and external sensor interrupt. DOMD[1:0] – Digital output mode (when not in SPI communication). 2’b00 = CMOS (push-pull) output. 2’b01 = Pull-up output. 2’b10 = Pull-down output. DOUT is inverted relative to DOSRC description below. 2’b11 = High impedance (disconnected) output. Default. DOSRC[1:0] – Digital output source (when not in SPI communication). 2’b00 = DOUT is a copy of the external interrupt comparator output. 2’b01 = DOUT is high when an ISO 15693 command has been recognized and is being processed. 2’b10 = DOUT is high when the RF field is available. 2’b11 = DOUT is the logical OR of EEFULL, ADCERR, LOWBAT, and OVLIM. If OSCEN=1, the output is AND’d with a modulated signal that is 1/32 second high (32 counts of osc1k) and 31/32 second low (992 counts of osc1k). BATCHK – Battery check at the start of logging. 0 = No battery check. 1 = Do a battery check in order to qualify the logging. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |