22 / 26 page ![]() TLS115D0 High Precision Voltage Tracker Application information Data Sheet 22 Rev. 1.00 2016-10-13 Based on the above calculation the proper PCB type and the necessary heat sink area can be determined with reference to the specification in “Thermal resistance” on Page 8. Example Application conditions: VIN = 13.5 V VOUT = VADJ =5V IOUT =100 mA Ta = 75°C Calculation of RthJA,max: PD =(VIN – VOUT) x IOUT + VIN x Iq = (13.5V – 5V) x 100 mA + 13.5 V x 3.5 mA = 0.897 W RthJA,max =(Tj,max – Ta) / PD = (150°C – 75°C) / 0.897 W = 83.61 K/W As a result, the PCB design must ensure a thermal resistance RthJA lower than 83.61 K/W. According to “Thermal resistance” on Page 8, at least 300 mm² heatsink area is required on the FR4 1s0p PCB, or the FR4 2s2p board can be used. 5.4 Further application information • For further information you may contact http://www.infineon.com/ |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|