| 전자부품 데이터시트 검색엔진 |
|
ADCMP395ARMZ 데이터시트(PDF) 12 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADCMP395ARMZ 데이터시트(HTML) 12 Page - Analog Devices |
|
12 / 18 page ![]() ADCMP394/ADCMP395/ADCMP396 Data Sheet Rev. B | Page 12 of 18 TYPICAL APPLICATIONS ADDING HYSTERESIS To add hysteresis, see Figure 33; two resistors are used to create different switching thresholds, depending on whether the input signal is increasing or decreasing in magnitude. When the input voltage increases, the threshold is above VREF, and when the input voltage decreases, the threshold is below VREF. Figure 33. Noninverting Comparator Configuration with Hysteresis The upper input threshold level is given by R2 R2 R1 V V REF IN_HI ) ( (2) Assuming RLOAD >> R2, RPULLUP. The lower input threshold level is given by PULLUP CC PULLUP REF LO IN R R2 R1 V R R2 R1 V V _ (3) The hysteresis is the difference between these voltages levels. ) ( UP PULL CC UP PULL REF HYS R R2 R2 R2 R1 V R R1 V V ) ( ) ( (4) WINDOW COMPARATOR FOR POSITIVE VOLTAGE MONITORING When monitoring a positive supply, the desired nominal operating voltage for monitoring is denoted by VM, IM is the nominal current through the resistor divider, VOV is the overvoltage trip point, and VUV is the undervoltage trip point. Figure 34. Positive Undervoltage/Overvoltage Monitoring Configuration Figure 34 illustrates the positive voltage monitoring input connection. Three external resistors, RX, RY, and RZ, divide the positive voltage for monitoring, VM, into the high-side voltage, VPH, and the low-side voltage, VPL. The high-side voltage is connected to the INA+ pin and the low-side voltage is connected to the INB− pin. To trigger an overvoltage condition, the low-side voltage (in this case, VPL) must exceed the VREF threshold on the INB+ pin. Calculate the low-side voltage, VPL, by the following: Z Y X Z OV REF PL R R R R V V V (5) In addition, RX + RY + RZ = VM/IM (6) Therefore, RZ, which sets the desired trip point for the overvoltage monitor, is calculated as M OV M REF Z I V V V R (7) To trigger the undervoltage condition, the high-side voltage, VPH, must be less than the VREF threshold on the INA− pin. The high-side voltage, VPH, is calculated by Z Y X Z Y UV REF PH R R R R R V V V (8) Because RZ is already known, RY can be expressed as Z M UV M REF Y R I V V V R (9) When RY and RZ are known, RX can be calculated by RX = (VM/IM) – RY − RZ (10) If VM, IM, VOV, or VUV changes, each step must be recalculated. OUTx INx– INx+ VREF = 2.5V VIN VCC = 5V R1 RLOAD RPULL-UP R2 VOUT VIN VIN_LOW VIN_HIGH OUTA INA+ INA– REF OUTB INB+ INB– VM RZ RY RX VPL VPH |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |