Back Button AD9554BCPZ Datasheet HTML 4Page - Analog Devices AD9554BCPZ Datasheet HTML 5Page - Analog Devices AD9554BCPZ Datasheet HTML 6Page - Analog Devices AD9554BCPZ Datasheet HTML 7Page - Analog Devices AD9554BCPZ Datasheet HTML 8Page - Analog Devices AD9554BCPZ Datasheet HTML 9Page - Analog Devices AD9554BCPZ Datasheet HTML 10Page - Analog Devices AD9554BCPZ Datasheet HTML 11Page - Analog Devices AD9554BCPZ Datasheet HTML 12Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 116 page
background image
AD9554
Data Sheet
Rev. D | Page 8 of 116
Parameter
Min
Typ
Max
Unit
Test Conditions/Comments
SINGLE-ENDED MODE
DC-coupled
Frequency Range (CMOS)
0.002
300
MHz
Minimum Input Slew Rate
Minimum limit imposed for jitter performance
DPLL Loop Bandwidth = 50 Hz
40
V/μs
DPLL Loop Bandwidth = 4 kHz
175
V/μs
Maximum loop bandwidth is fPFD/50
Input Voltage High, VIH
VDD − 0.5
V
Input Voltage Low, VIL
0.5
V
Input Resistance
30
kΩ
Input Capacitance
5
pF
Minimum Pulse Width High
1.5
ns
Minimum Pulse Width Low
1.5
ns
REFERENCE MONITORS
Table 6.
Parameter
Min
Typ
Max
Unit
Test Conditions/Comments
REFERENCE MONITORS
Reference Monitor
Loss of Reference Detection Time
1.15
DPLL PFD period
Nominal phase detector period = R/fREF, where R is the
frequency division factor determined by the R divider,
and fREF is the frequency of the active reference
Frequency Out-of Range Limits
2
105
Δf/fREF (ppm)
Programmable (lower bound subject to quality of the
system clock [SYSCLK]); SYSCLK accuracy must be less
than the lower bound
Validation Timer
0.001
65.535
sec
Programmable in 1 ms increments
REFERENCE SWITCHOVER SPECIFICATIONS
Table 7.
Parameter
Min
Typ
Max
Unit
Test Conditions/Comments
MAXIMUM OUTPUT PHASE PERTURBATION
(PHASE BUILD-OUT SWITCHOVER)
Assumes a jitter-free reference; satisfies
Telcordia GR-1244-CORE requirements; base
loop filter selection bit set to 1b or all active
references
50 Hz DPLL Loop Bandwidth
High phase margin mode; 19.44 MHz to
174.70308 MHz; DPLL bandwidth = 50 Hz;
49.152 MHz signal generator used for system
clock source
Peak
±20
±130
ps
Steady State
±20
±130
ps
Time Required to Switch to a New Reference
Phase Build-Out Switchover
10
DPLL
PFD
period
Calculated using the nominal phase detector
period (NPDP = R/fREF); the total time required
is the time plus the reference validation time,
plus the time required to lock to the new
reference



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com