Back Button BMP180 Datasheet HTML 18Page - Bosch Sensortec GmbH BMP180 Datasheet HTML 19Page - Bosch Sensortec GmbH BMP180 Datasheet HTML 20Page - Bosch Sensortec GmbH BMP180 Datasheet HTML 21Page - Bosch Sensortec GmbH BMP180 Datasheet HTML 22Page - Bosch Sensortec GmbH BMP180 Datasheet HTML 23Page - Bosch Sensortec GmbH BMP180 Datasheet HTML 24Page - Bosch Sensortec GmbH BMP180 Datasheet HTML 25Page - Bosch Sensortec GmbH BMP180 Datasheet HTML 26Page - Bosch Sensortec GmbH Next Button
Zoom Inzoom in Zoom Outzoom out
 22 / 29 page
background image
Data sheet
BMP180
Page 22
BST-BMP180-DS000-12 | Revision 2.8 | May 2015
Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third
parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
S
ACKS
Module address
write 0xEE
ACKS
Register address
e.g. 0xF6
MSB e.g.
ADC result 0x5C
ACKS
Module address
read 0xEF
Restart
ACKM
LSB e.g.
ADC result 0x96
NACKM
SCL
PR
OM
SDA
P
5.5 Read A/D conversion result or E2PROM data
To read out the temperature data word UT (16 bit), the pressure data word UP (16 to 19 bit) and
the E2PROM data proceed as follows:
After the start condition the master sends the module address write command and register address.
The register address selects the read register:
E2PROM data registers
0xAA to 0xBF
Temperature or pressure value UT or UP 0xF6 (MSB), 0xF7 (LSB), optionally 0xF8 (XLSB)
Then the master sends a restart condition followed by the module address read that will be
acknowledged by the BMP180 (ACKS). The BMP180 sends first the 8 MSB, acknowledged by the
master (ACKM), then the 8 LSB. The master sends a "not acknowledge" (NACKM) and finally a stop
condition.
Optionally for ultra high resolution, the XLSB register with address 0xF8 can be read to extend the
16 bit word to up to 19 bits; refer to the application programming interface (API) software rev. 1.1
(“BMP180_ API”, available from Bosch Sensortec).
Figure 9: Timing diagram read 16 bit A/D conversion result



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com