| 전자부품 데이터시트 검색엔진 |
|
BMP280 데이터시트(PDF) 18 Page - Bosch Sensortec GmbH |
|
|
|||||||||||||||||||||||||||||
BMP280 데이터시트(HTML) 18 Page - Bosch Sensortec GmbH |
|
18 / 49 page ![]() Datasheet BMP280 Digital Pressure Sensor Page 18 BST-BMP280-DS001-19 | Revision 1.19 | January 2018 Bosch Sensortec © Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are subject to change without notice. Not intended for publication. 3.7 Current consumption The current consumption depends on ODR and oversampling setting. The values given below are normalized to an ODR of 1 Hz. The actual consumption at a given ODR can be calculated by multiplying the consumption in Table 12 with the ODR used. The actual ODR is defined either by the frequency at which the user sets forced measurements or by oversampling and tstandby settings in normal mode in Table 14. Table 12: Current consumption Oversampling setting Pressure oversampling Temperature oversampling IDD [µA] @ 1 Hz forced mode Typ Max Ultra low power ×1 ×1 2.74 4.16 Low power ×2 ×1 4.17 6.27 Standard resolution ×4 ×1 7.02 10.50 High resolution ×8 ×1 12.7 18.95 Ultra high resolution ×16 ×2 24.8 36.85 3.8 Measurement timings The rate at which measurements can be performed in forced mode depends on the oversampling settings osrs_t and osrs_p. The rate at which they are performed in normal mode depends on the oversampling setting settings osrs_t and osrs_p and the standby time tstandby. In the following table the resulting ODRs are given only for the suggested osrs combinations. 3.8.1 Measurement time The following table explains the typical and maximum measurement time based on selected oversampling setting. The minimum achievable frequency is determined by the maximum measurement time. Table 13: measurement time Oversampling setting Pressure oversampling Temperature oversampling Measurement time [ms] Measurement rate [Hz] Typ Max Typ Min Ultra low power ×1 ×1 5.5 6.4 181.8 155.6 Low power ×2 ×1 7.5 8.7 133.3 114.6 Standard resolution ×4 ×1 11.5 13.3 87.0 75.0 High resolution ×8 ×1 19.5 22.5 51.3 44.4 Ultra high resolution ×16 ×2 37.5 43.2 26.7 23.1 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |