| 전자부품 데이터시트 검색엔진 |
|
TDSUSBF 데이터시트(PDF) 24 Page - TEKTRONIX, INC. |
|
|
|||||||||||||||||||||||||||||
TDSUSBF 데이터시트(HTML) 24 Page - TEKTRONIX, INC. |
|
24 / 46 page ![]() Clock recovery system DPO Models Requires Option ST6G or Option MTH MSO Models Standard Clock recovery phase locked loop bandwidth Fixed at FBaud/1600 Clock recovery jitter (RMS) <0.25% bit period + 2 psRMS for PRBS data patterns <0.25% bit period + 1.5 psRMS for repeating "0011” data pattern Minimum signal amplitude needed for clock recovery 1 divp-p up to 1.25 Gbaud 1.5 divp-p above 1.25 Gbaud Tracking/Acquisition range ±2% of requested baud Clock recovery frequency range 1.5 MBaud to 3.125 GBaud. Recovered clock and regenerated data available for use with a BERT. Serial pattern trigger DPO Models Requires Option ST6G MSO Models Standard NRZ-Encoded Data Up to 64 bit serial word recognizer, bits specified in binary (high, low, don't care) or hex format Trigger on NRZ-encoded data up to 1.25 GBaud 8b/10b-Encoded Data Trigger on 8b/10b-encoded data at the following rates: 1.25 to 1.65, 2.1 to 3.2, 3.8 to 5.1, and 5.4 to 6.25 GBaud. Pattern length up to 40 bits (1 to 4 valid 10-bit characters) Alignment character is K28.5 (either disparity) Communications-related triggers Support for AMI, HDB3, BnZS, CMI, MLT3, and NRZ encoded communications signals. Select among isolated positive or negative one, zero pulse form, or eye patterns as applicable to the standard. DPO Models Requires Option MTH MSO Models Standard Bus triggers maximum toggle rate I2C, SPI, RS-232/422/485/UART: 10 Mb/s USB: low-speed, full-speed CAN: 1 Mb/s LIN: 100 kb/s MIL-STD-1553B: 2 Mb/s Logic pattern trigger (MSO Models) Threshold range P6780: –2 to +4.5 V P6717A/P6750: –1.5 to +4 V Threshold accuracy ±100 mV + 3% of threshold setting Enhanced triggering Enhanced triggering corrects the difference in timing between the trigger path and the acquired data path (supports all Pinpoint trigger types on both A- and B-Events except pattern trigger); Default On (user-selectable); Not available in FastAcq mode. Line trigger Trigger on power line signal. Level fixed at 0 V. Datasheet Pinpoint® trigger system 24 www.tek.com |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |