18 / 48 page ![]() Shunt Voltage Temperature Bus Voltage ALERT (ALATCH = 0) (APOL = 0) (CNVR = 1) Power Shunt Over Voltage Threshold Bus Under Voltage Threshold Over Temp Threshold Power Over Limit Threshold BUV SET SOV SET BUV CLEAR SOV & BUV SET SOV CLEAR BUV & OT SET BUV & OT & OP SET - No diag. error - Conversion Complete Reported Figure 7-6. Multi-Alert Configuration 7.4 Device Functional Modes 7.4.1 Shutdown Mode In addition to the two conversion modes (continuous and triggered), the device also has a shutdown mode (selected by the MODE bits in ADC_CONFIG register) that reduces the quiescent current to less than 5 µA and turns off current into the device inputs, reducing the impact of supply drain when the device is not being used. The registers of the device can be written to and read from while the device is in shutdown mode. The device remains in shutdown mode until another triggered conversion command or continuous conversion command is received. The device can be triggered to perform conversions while in shutdown mode. When a conversion is triggered, the ADC will start conversion; once conversion completes the device will return to the shutdown state. Note that the shutdown current is specified with an inactive communications bus. Active clock and data activity will increase the current consumption as a function of the bus frequency as shown in Shutdown IQ vs. Clock Frequency. 7.4.2 Power-On Reset Power-on reset (POR) is asserted when VS drops below 1.26V (typical) at which all of the registers are reset to their default values. A manual device reset can be initiated by setting the RST bit in the CONFIG register. The default power-up register values are shown in the reset column for each register description. Links to the register descriptions are shown in Section 7.6. 7.5 Programming 7.5.1 Serial Interface The primary communication between the INA229-Q1 and the external MCU is through the SPI bus, which provides full-duplex communications in a main-secondary configuration. The external MCU is always the primary or main SPI device, sending command requests on the MOSI pin, and receiving device responses on the MISO pin. The INA229-Q1 is always an SPI secondary device, receiving command requests and sending responses (status, measured values) to the external MCU over the MISO pin. • SPI is a 4-pin interface with pins as: – CS - SPI Chip Select (input) – SCLK - SPI Clock (input) – MOSI - SPI Secondary In / Main Out data (input) INA229-Q1 SLYS024A – MAY 2020 – REVISED JUNE 2021 www.ti.com 18 Submit Document Feedback Copyright © 2021 Texas Instruments Incorporated Product Folder Links: INA229-Q1 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |