| 전자부품 데이터시트 검색엔진 |
|
AM79C850KC 데이터시트(PDF) 29 Page - Advanced Micro Devices |
|
|
|||||||||||||||||||||||||||||
AM79C850KC 데이터시트(HTML) 29 Page - Advanced Micro Devices |
|
29 / 97 page ![]() P R E L I M I N A R Y AMD 29 SUPERNET 3 (if transmitting), releases the token, and no further transmissions can occur until the pin is deasserted. During the time that the TRANSMIT INHIBIT function is enabled the network timers and state machines operate normally. As a result of the change to the FLXI pin, which of the two functions is selected depends upon the state of FLXI bits, as follows: FLXI Pin FLXI1 FLXI0 Function Implemented 0 0 0 Normal Operation 1 0 0 Normal Operation 0 0 1 Normal Operation 1 0 1 FLUSH received frame 0 1 0 Normal Operation 1 1 0 INHIBIT transmission 0 1 1 Reserved 1 1 1 Reserved Upon reset, the FLXI1:0 bits would read all zeros. Single Frame Receive Mode The Single Frame Receive Mode function has been removed from the SUPERNET 3. All associated status, modes and commands are deleted and replaced with reserved. This causes the following changes: 1. Status Register 2 Upper: The ‘Receive Frame’ (SRCVFRM) bit 10 and ‘Receive Frame Counter Overflow’ (SRFRCTOV) bit 9 are now reserved and return a value of zero when read. 2. Command Register 2: The ‘Enable Receive Single Frame’ command (0x40) is no longer a valid command. This is now reserved. 3. Mode Register 1: The ‘Single-Frame Receive Mode’ bit [15] is no longer valid. It is now a reserved bit and shall return a value of zero when read. Receive Queue Operation SUPERNET 3 provides a new feature where the user can configure the buffer memory for incoming valid frame into two separate receive queues. The type of frames that each queue would receive is selected in a separate register, the Frame Selection Register (FRSELREG). To enable two receive queues operation, MENDRCV bit in Mode Register 3 (MDREG3) needs to be set. If this bit is cleared, which is the case at the time of reset, then SUPERNET 3 behaves like F+ (i.e only one receive queue is supported, and SUPERNET 3 defaults to Receive Queue 1). If MDREG3 bit 11, MENDRCV and both RECVX3:0 in Frame Selection Register (FRSELREG) is programmed to be “0000” then the SUPERNET 3 would behave like FORMAC+ and the second queue is ignored. However, if one of the RECVX3:0 bits in FRSELREG are programmed to be “0000” then the corresponding queue would receive all frames except the frame type selected for the other queue. Only the second receive queue (i.e. RECV2) can be programmed to be “0000”. Programming the RECV1 bits in the Frame Selection Register (FRSELREG) with “0000” and RECV2 bits with a non-zero selection, will result in no data being written in the RECV1 queue. Only the frame type selected by RECV2 bits will be received in the second queue. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |