50 / 98 page ![]() 32 General Mounting Considerations Section 10-3 10-3-3 Installation of Multiple Systems When two or more MS4800 systems with the same scan code are mounted in close proximity and in alignment with each other, precautions should be taken to avoid one system interfering with another. This can be corrected by mount- ing the transmitters and receivers back-to-back or stacked. The scan code feature of the MS4800 system allows for placement of systems in close proximity and in line with each other. The distinctive coding of the beams provide for unique operation of a system while in view of another sys- tem with a different scan code. Two unique codes are available on the MS4800. 10-3-4 Detection Zone The system detection zone is delineated by the inside edge of the transmitter and receiver endcaps. The area outside these marks is not protected. Position the system so that it is only possible to access the danger point through the detection zone. 10-3-5 Alignment Physical alignment of the transmitter and receiver is easiest when the system is in the automatic start operating mode with Fixed Blanking inactive. The units should be in the same plane and at equal height. The Individual Beam Indicators will light when a part of the Safety Light Cur- tain is out of alignment. 10-3-6 Input Power Requirements The system operates directly from 24 VDC ±20%. Power to the system must come from a power supply which meets the requirements of EN/IEC60204-1 and EN/IEC 61496-1. The power supply must guarantee safe insulation from the mains voltage in accordance with IEC60742 and be able to cover a drop of supply voltage of at least 20 ms. Omron offers suitable power supplies. The power supply must not supply any other parts of the machine with power other than the safety components connected. Transmitters and receivers must be supplied from a shared power supply and must be fused against overcurrent. Machine 1 Machine 2 PREFERRED INSTALLATION Code A Code A Machine 1 Machine 2 NOT RECOMMENDED INSTALLATION Code A Code A Machine 1 Machine 2 Code A Code B |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |