| 전자부품 데이터시트 검색엔진 |
|
SCD42-D-R2 데이터시트(PDF) 12 Page - Sensirion AG Switzerland |
|
|
|||||||||||||||||||||||||||||
SCD42-D-R2 데이터시트(HTML) 12 Page - Sensirion AG Switzerland |
|
12 / 21 page ![]() www.sensirion.com Version 1 – March 2022 12/21 3.6.5 set_ambient_pressure Description: The set_ambient_pressure command can be sent during periodic measurements to enable continuous pressure compensation. Note that setting an ambient pressure using set_ambient_pressure overrides any pressure compensation based on a previously set sensor altitude. Table 17: set_ambient_pressure I2C sequence description Write (hexadecimal) Input parameter: Ambient pressure Response parameter: - Max. command duration [ms] length [bytes] signal conversion length [bytes] signal conversion 0xe000 3 word[0] = ambient P [Pa] / 100 - - 1 Example: set ambient pressure to 98’700 Pa Write 0xe000 0x03db 0x42 (hexadecimal) Command Ambient P = 98’700 Pa CRC of 0x03db |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |