23 / 39 page ![]() ft≈ 12π nVin nVout+VinRsenseSecGTV Rsense 1FckVCSFSR 1TsampPIDCC_Igain (16) The gain can be set as: PIDCC_Igain=ft2πRsenseFckVCSFSRTsamp RsenseSecGTV nVoutVin+1n (17) It is advisable to keep the cutoff frequency at least below 1/5 of the loop sampling frequency, i.e. below 8 kHz. If no need for fast transient response is required, a lower bandwidth helps in limiting the control noise. 8.6.5 Cable drop compensation The cable drop compensation allows to increase the output voltage of the converter proportionally to the current sensed through the CSP/CSM pins. The cable drop compensation is disabled when the output voltage set by the USB-PD port is above a programmable threshold. The cable resistance to be compensated can be programmed in the configuration parameters. 8.7 Fault management The IC includes many protections to avoid damage to the converter or to the load in abnormal or failure conditions. 8.7.1 Fault modes The faults can be either managed as auto-restart, latched, or conditioned restart.The behavior of each fault is described in Fault summary. 8.7.1.1 Auto-restart mode In auto-restart mode, once the protection is tripped, the switching activity is stopped, and the condition is maintained until VPVCC goes below the V PVCCOff restart voltage and then rises again to V PVCCOn for six times. Ultimately, this results in a low frequency intermittent operation (Hiccup-mode operation). 8.7.1.2 Latched mode In latched mode the protection is maintained until the input main is removed. During this time the HV generator is activated periodically to cycle the supply voltage between V PVCCOn and V PVCCOff. The condition is indefinitely maintained until the AC mains is removed triggering a brown-out or an X-Cap discharge fault which clears all fault conditions. 8.7.1.3 Conditioned restart mode Faults like the overtemperature or the brown-out, require the fault condition to disappear before the system can restart. When the fault condition is no longer present the system restarts after VPVCC goes below V PVCCOff restart voltage and then rises again to V PVCCOn. 8.7.2 Soft-start timeout As a protection from secondary side failures, the IC stops switching if no signal is received from the secondary side before the SS pin voltage reaches VSSEND. This fault is managed as auto-restart. 8.7.3 Soft-start overvoltage protection The primary side IC includes a detection circuit to avoid generating overvoltage on the output when the secondary side is not active. The OV function operates only during primary side soft-start: as the secondary side takes control, the protection is managed by the secondary side. The overvoltage function of the ST-ONEMP device monitors the voltage on the OVP pin during HS MOSFET's on-time, when the voltage generated by the auxiliary winding tracks converter's output voltage. ST-ONEMP Fault management DS13989 - Rev 2 page 23/39 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |