  SLG5NT026 Datasheet HTML 1Page - Renesas Technology Corp SLG5NT026 Datasheet HTML 2Page - Renesas Technology Corp SLG5NT026 Datasheet HTML 3Page - Renesas Technology Corp SLG5NT026 Datasheet HTML 4Page - Renesas Technology Corp SLG5NT026 Datasheet HTML 5Page - Renesas Technology Corp SLG5NT026 Datasheet HTML 6Page - Renesas Technology Corp SLG5NT026 Datasheet HTML 7Page - Renesas Technology Corp SLG5NT026 Datasheet HTML 8Page - Renesas Technology Corp SLG5NT026 Datasheet HTML 9Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 10 page
background image
000-005NT026-101
Page 5 of 9
SLG5NT026
Delay Time and Slew Rates
The two components of controlling the application of FET source voltage to the load are a fixed time delay before beginning turn
on of the FET (DLY_t below) and the Slew Time of the source voltage (Slew_t below). The Delay Time before gate voltage to the
FET is applied and the corresponding delay is 250
µs independent of FET drain voltage, source voltage or SLG5NT026 supply
voltage.
Having control over the Slew Rate of the FET’s source voltage as the FET is turning on is important in controlling dv/dt caused
transients. A power FET, for example, switching a 5 V rail which has a total of 500
µF of decoupling, fully on in 10 µs will generate
a 250 A current surge which is very undesirable. If the FET turn on time can be stretched to 1ms, the current surge to charge the
decoupling capacitors is reduced to 2.5 A. The SLG5NT026 controls slew rate of a FET’s source voltage as it is turned on. A
range of slew rates are available as device order options. Obviously the time to fully slew the source voltage to fully on is a
function of the drain supply voltage. The table and graph below shows source voltage ramp times for various slew rates supported
by the SLG5NT026 for a range of specific source voltages.
* The minimum time that ON can be de-asserted between switching cycles is 100
µs.
Slew Rates
(V/ms)
Ramp Times (ms) vs. Source Voltages (V)
1.1 V
1.5 V
1.8 V
3.3 V
5.0 V
12 V
18.5 V
4.00
0.28
0.38
0.45
0.83
1.25
3.00
4.63
2.00
0.56
0.76
0.90
1.66
2.50
6.00
9.26
6
8
10
Ramp Times (ms) vs. Source Voltage for Various Slew Rates (v/ms)
4.00
2.00
0
2
4
6
8
10
1
2
3
4
5
6
7
Source Voltage
Ramp Times (ms) vs. Source Voltage for Various Slew Rates (v/ms)
4.00
2.00
0
2
4
6
8
10
1
2
3
4
5
6
7
Source Voltage
Ramp Times (ms) vs. Source Voltage for Various Slew Rates (v/ms)
4.00
2.00



Html Pages

1 2 3 4 5 6 7 8 9 10


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com