| 전자부품 데이터시트 검색엔진 |
|
NB650GL 데이터시트(PDF) 13 Page - MPS Industries, Inc. |
|
|
|||||||||||||||||||||||||||||
NB650GL 데이터시트(HTML) 13 Page - MPS Industries, Inc. |
|
13 / 20 page ![]() NB650/NB650H – 6A, 28V, FAST-TRANSIENT, SYNCHRONOUS STEP-DOWN CONVERTERS NB650/NB650H Rev. 1.13 www.MonolithicPower.com 13 10/7/2019 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. Preliminary Specifications Subject to Change © 2019 MPS. All Rights Reserved. on the output and triggers OCP immediately. This is short circuit protection (SCP). Under OCP/SCP condition, NB650 will latch off. The converter needs power cycle to restart. NB650H will try to recover from OCP/SCP fault with hiccup mode. That means in OCP/SCP protection, the NB650H will disable the output power stage, discharge soft-start capacitor and then automatically try to start again. If the over- current condition still holds after soft-start ends, the NB650H repeats this operation cycle till over- current fault is removed and output rises back to regulation level. Over/Under-Voltage Protection The NB650/NB650H monitors the output voltage through the FB voltage to detect overvoltage and under voltage on the output. When the FB voltage exceeds 0.8V, the over-voltage protection (OVP) triggers. Once OVP triggers, the LS-FET is always on while the HS-FET is always off. The device needs to power cycle to power up again. Under-voltage protection (UVP) triggers when the FB voltage is below 0.4V. Usually, UVP accompanies hitting the current limit, which results in SCP. UVLO Protection The NB650/NB650H has under-voltage lockout (UVLO) protection. When VIN exceeds the UVLO- rising threshold voltage, the NB650/NB650H powers up. It shuts off when VIN falls below the UVLO-falling threshold voltage. This is non-latch protection. Thermal Shutdown The NB650/NB650H employs thermal shutdown by internally monitoring the temperature of the junction. If the junction temperature exceeds the threshold value (typically 150°C), the converter shuts off. This is non-latch protection. There is about 25°C hysteresis. Once the junction temperature drops to around 125°C, it initiates a soft-start. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |