48 / 53 page ![]() Flowcharts and pseudo codes M50FW040 48/53 12 Flowcharts and pseudo codes Figure 18. Program flowchart and pseudo code 1. A Status check of b1 (Protected Block), b3 (VPP invalid) and b4 (Program Error) can be made after each Program operation by following the correct command sequence. 2. If an error is found, the Status Register must be cleared before further Program/Erase Controller operations. Write 40h or 10h AI03407 Start Write Address & Data Read Status Register YES NO b7 = 1 YES NO b3 = 0 NO b4 = 0 VPP Invalid Error (1, 2) Program Error (1, 2) Program command: – write 40h or 10h – write Address & Data (memory enters read status state after the Program command) do: –read Status Register if Program/Erase Suspend command given execute suspend program loop while b7 = 1 If b3 = 1, VPP invalid error: – error handler If b4 = 1, Program error: – error handler YES End YES NO b1 = 0 Program to Protected Block Error (1, 2) If b1 = 1, Program to protected block error: – error handler Suspend Suspend Loop NO YES FWH Interface Only |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|