| 전자부품 데이터시트 검색엔진 |
|
SC1933C 데이터시트(PDF) 18 Page - Power Integrations, Inc. |
|
|
|||||||||||||||||||||||||||||
SC1933C 데이터시트(HTML) 18 Page - Power Integrations, Inc. |
|
18 / 28 page ![]() Rev. C 11/18 18 SC1933C/SC1936C www.power.com Figure 17. Discontinuous Conduction Mode Current Waveform, KP > 1. Maximum Operating Flux Density, B M (Gauss) A maximum value of 3800 gauss at the peak device current limit (at 132 kHz) is recommended to limit the peak flux density at start-up and under output short-circuit conditions. Under these conditions the output voltage is low and little reset of the transformer occurs during the switch off-time. This allows the transformer flux density to staircase beyond the normal operating level. A value of 3800 gauss at the peak current limit of the selected device together with the built-in protection features of SC1933C/SC1936C IC provide sufficient margin to prevent core saturation under start-up or output short- circuit conditions. Transformer Primary Inductance, (LP) Once the lowest operating input voltage, switching frequency at full load, and required VOR are determined, the transformers primary inductance can be calculated. The PIXls design spreadsheet can be used to assist in designing the transformer. Quick Design Checklist As with any power supply, the operation of all SC1933C/SC1936C designs should be verified on the bench to make sure that component limits are not exceeded under worst-case conditions. As a minimum, the following tests are strongly recommended: 1. Maximum Drain Voltage – Verify that V DS of SC1933C/SC1936C do not exceed >650 V of maximum continuous drain voltage at the highest input voltage and peak (overload) output power in normal operation and during start-up. Also make sure that SR FET do not exceed >90% of breakdown voltage under above mentioned conditions. 2. Maximum Drain Current – At maximum ambient temperature, maximum input voltage and peak output (overload) power. Review drain current waveforms for any signs of transformer saturation or excessive leading-edge current spikes at start-up. Repeat tests under steady-state conditions and verify that the leading edge current spike is below I LIMIT(MIN) at the end of tLEB(MIN). Under all conditions, the maximum drain current for the primary switch should be below the specified absolute maximum ratings. 3. Thermal Check – At specified maximum output power, minimum input voltage and maximum ambient temperature, verify that temperature specification limits for SC1933C/SC1936C IC, transformer, output SR FET, and output capacitors are not exceeded. Enough thermal margin should be allowed for part-to-part variation of the R DS(ON) of the SC1933C/SC1936C IC. Under low-line, maximum power, a maximum SC1933C/SC1936C SOURCE pin temperature of 110 °C is recommended to allow for these variations. KP ≡ KDP = T = 1/fS T = 1/fS (1-D) × T (1-D) × T = t t D × T D × T (b) Borderline Discontinuous/Continuous, KP = 1 (a) Discontinuous, KP > 1 Primary Secondary Primary Secondary PI-2578-103114 (1-D) × T t |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |